My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_2013-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2024 4:22:39 PM
Creation date
6/3/2020 9:54:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2014
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_2013-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MW San Joaquin County - nff�lz_ Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sw ov.org/ehd <br />Facility Name: Facility Address: Date: <br />Tracy Valero 2375 N TRACY BLVD, TRACY September 29, 2014 <br />Item # I Remarks <br />104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Tank Information forms for the 87, 89, and 91 tanks are not current in CERS. <br />87 Tank Form (TAO 189705): <br />Lists the primary piping as flexible; this piping is fiberglass. <br />Lists 'none' for the riser pipe primary containment; the riser is steel. <br />91 Tank Form (TA0189706): <br />Incorrectly listed as midgrade unleaded; this tank contains premium unleaded. <br />Does not list an overfill protection; the overfill prevention being used is fill tube shut off valve. <br />89 Tank Form (TA0189707): <br />Incorrectly listed as premium unleaded; this tank contains midgrade unleaded. <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required information, and submit for review by the EHD. This is a repeat violation, Class II. <br />106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and/or not approved by the EHD. The monitoring plans for all four tanks contained <br />inaccurate information. <br />87, 89, and 91 Monitoring Plans: <br />The monitoring plan states that leak arms and failure/disconnect do not trigger pump shutdown; the monitoring panel <br />is programmed for pump shut down for either circumstance. <br />The leak detector MLLD manufacturer and model list two separate leak detectors; the leak detector being used is a <br />VMI 99-LD2000. <br />ELD testing is marked as ayes' under Periodic System Testing; this site was required to perform a one-time ELD <br />test and is not conducting periodic ELD testing. <br />The'second person having responsibility' was left blank. <br />Used Oil Monitoring Plan: <br />ELD testing is marked as a 'yes' under Periodic System Testing; this site was required to perform a one-time ELD <br />test and is not conducting periodic ELD testing. <br />The'second person having responsibility' was left blank. <br />The comments sections addressing the overfill prevention exemption lists "26:35-63'; the correct code section <br />should be listed as CCR 2635(B)(3). <br />The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log into <br />CERS, make the necessary changes, and submit for review by the EHD. This is a repeat violation, Class II. <br />112 HSC 25284.2 Failed to test spill containers annually. <br />Annual spill container testing for the 87 spill container was last performed on August 8, 2013 and was completed on <br />September 29, 2014, one month past due. This test is required once every 12 months. Take all necessary precautions <br />to ensure testing is performed in a timely manner. This is a repeat violation, Class ll. <br />yeu/ed I STACY RIVERA, Senior REHS <br />Page 4 of 8 <br />(209) 468-3440 09/29/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.