Laserfiche WebLink
C <br />n <br />' <br />4162 Id Street <br />Galt, CA 95632 <br />(209) 744-0113 Fax (209) 744-0116 <br />E.O. VR -203/204 <br />Veeder-Root Vapor Polisher Operability Test Form <br />Permit Number: <br />Date 12-18-13 <br />Site Name: TRACY VALERO <br />Technician: DAVE WINKLER <br />Site Address, 2375 TRACY BL <br />VST: DAVID WINKLER # 1360 <br />City: TRACY CA Zip: <br />Veeder-Root: DAVID WINKLER # B34975 <br />District: SJV j <br />Calibration Date: 11-5-13 <br />TEST INFORMATION <br />Calibration date for digital manometer (must be within 6 months of the test) <br />11-1-13 <br />Ending value for digital manometer drift test (must be 0.01 in. w.c. or less) <br />0 <br />Calibration date for thermometer (must be with 6 months of the test) <br />NA <br />Vapor polisher valve close date and time (must have been closed for at least 2 hours) <br />12-18-i3 1 lAM <br />Atmospheric pressure sensor serial number <br />7072 <br />PRESSURE INTEGRITY TEST <br />9.2.2 <br />Nitrogen gas flow rate (scfh) <br />18CFH <br />Starting pressure (in. w.c.) <br />8.06 <br />Final pressure at I minute (in. w.c.) <br />8.14 <br />Is the final pressure > 7.0 in. w.c:? <br />Is the difference between the starting and final pressure < 0.5 in. w.c.? <br />Yes <br />Yes <br />NOTES: iif the final pressure is not > 7.0 in. w.c. and the difference is not < 0.5 in. w.c., then the vapor polisher is not in <br />comnliance. <br />FLOW TEST <br />Nitrogen gas flow rate (scfh) 18SCFII <br />Pressure (in. w.c.) 1.76 <br />Is the pressure between 1.69 and 2.25 in. w.c.? Yes <br />NOTES: 'The flow rate must be M0 * 0.2 scth. <br />'The pressure must be between 1.69 and 2.26 in. w.c. or the vapor polisher is not in compliance. <br />'Three-way valve must be returned to normal (open) operating position after testing is completed. <br />'PMC valve mode must be re -set to automatic after testine is completed. <br />VAPOR VANE THERMOMETER TEST <br />7.3.2 <br />Vapor polisher ambient temperature <br />67.03 <br />Vapor polisher outlet temperature <br />68.98 <br />Difference between ambient and outlet temperatures <br />1.95 <br />Is the difference less than 10° F? If not, proceed to section 9.2.1 <br />Yes <br />9.2.2 <br />Vapor polisher ambient temperature <br />Vapor polisher outlet temperature <br />Difference between ambient and outlet temperatures <br />Is the difference less than 10° F? If not, proceed to section 9.2.4 <br />No <br />9.2.4 & 9.2.5 <br />Vapor polisher ambient temperature <br />Vapor polisher outlet temperature <br />Calibrated thermometer ambient temperatures <br />