My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_2013-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2024 4:22:39 PM
Creation date
6/3/2020 9:54:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2014
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_2013-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />Difference between outlet temperature and the calibrated thermometer <br />Is the difference less than 10° F? If not, the outlet thermometer does not meet specifications <br />No <br />Difference between ambient temperature and the calibrated thermometer <br />Is the difference less than 10° F? If not, the ambient thermometer does not meet specifications <br />UST THERMOMETER TEST <br />UST #i <br />7.3.3 <br />T5 temperature <br />54.229 <br />T4 temperature <br />54.426 <br />Difference between T5 and T4 tem eratures <br />.003 <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />Yes <br />9.1 <br />T5 temperature <br />Calibrated thermometer ambient temperature <br />Difference between T5 and calibrated thermometer <br />Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br />UST #2 <br />§7.3.3 <br />T5 temperature <br />55.992 <br />T4 temperature <br />55.029 <br />Difference between T5 and T4 temperatures <br />.963 <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />Yes <br />9.1 <br />T5 temperature <br />Calibrated thermometer ambient temperature <br />Difference between T5 and calibrated thermometer <br />Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br />UST #3 <br />§7.3.3, <br />T5 temperature <br />59.485 <br />T4 temperature <br />59.663 <br />Difference between T5 and T4 temperatures <br />.178 <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />YES PASS <br />9.1 <br />T5 temperature <br />Calibrated thermometer ambient temperature <br />Difference between T5 and calibrated thermometer <br />Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br />ATMOSPHERIC PRESSURE SENSOR "GEST <br />Atmospheric pressure sensor reading (psi) <br />-0.081 <br />Atmospheric ,pressure sensor reading (in. mercury) <br />29.76 <br />Atmospheric pressure from local source (in. mercury) <br />29.82 <br />Difference between local source and pressure sensor reading (A) <br />.06 <br />0.10 x local source (B) <br />2.98 <br />Is A <_B? If not, the vapor polisher is not compliance <br />Yes <br />NOTES: `Conversion from pressure (psi) to pressure (in. mercury) Is: (psi +14,7) x 2.036 <br />I declare, under penalty of perjury under the laws of the state of California that based on information and belief formed after <br />reasonable inquiry, The statements and irxformation provided in this document are true, accurate, and complete. <br />Signature of Technician: _ Date: 1.2-18-13 <br />