My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7272
>
2300 - Underground Storage Tank Program
>
PR0231939
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2023 12:58:25 PM
Creation date
6/3/2020 9:55:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #3144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231939_7272 WEST_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County ' s -0 201-,' <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 JV' ,; I <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s' ov.or % d ' �✓ -' `� <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />QUIK STOP MARKET #3144 71UST <br />Facility Address: <br />7272 WEST LN, STOCKTON <br />Date: <br />July 24, 2017 <br />System Observations <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />o V ❑ R o COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />o V n R n COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R o COS <br />325 <br />CCR 2717.1(1) <br />Deposited petroleum into a red tagged UST <br />o V a R o COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />o V ❑ R a COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />o V a R a COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V a R ❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />o V o R o COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />o V o R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />a V a R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />o V o R o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />n V ❑ R o COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V n R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V a R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1; CLASS ll, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. The annual monitoring system <br />certification testing reports for 2014, 2015 and 2016 were not available to review during today's inspection. Also <br />daily alarm logs for the months of August and December 2016, and January, February, June 2017 were not <br />available to review during today's inspection. These records shall be maintained on site for at least three years. <br />Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br />maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br />field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; <br />(6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br />monitoring records for the last three years on site and submit copies to the EHD. <br />This is a repeat violation, Class II. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />FA0002570 PR0231939 SCO01 07/24/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.