Laserfiche WebLink
STATE OF CALIFORNIA "`b ." `o <br />' V i <br />STATE WATER RESOURCES CONTROL BOARD ; g <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. "- <br />MARK ONLY ❑ 1 NEW PERMIT <br />❑ <br />3 RENEWAL PERMIT ® 5 CHANGE OF INFORMATION <br />❑ 7 PERMANENTLY CLOSED ON SITI <br />ONE ITEM ❑ 2 INTERIM PERMIT <br />❑ <br />4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE <br />❑ 8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br />Lawrence Livermore National Laboratory Site 300 <br />1. TANK DESCRIPTION COMPLETE ALL ITEMS - SPECIFY iF UNKNOWN <br />A OWNER'S TANK 1. D. M $75-D1U2 <br />B. MANUFACTURED BY: Modern Welding Co., Inc. <br />C. DATE INSTALLED(MO/DAY/YEAR) 7/20/92 <br />D. TANK CAPACITY IN GALLONS: 3000 <br />11. TANK CONTENTS IF A-1 IS MARKED. COMPLETE TEM C. <br />A. a 1 MOTOR VEHICLE FUEL <br />❑ 4 OIL <br />& <br />C. to REGULAR UNLEADED <br />lb PREMIUM <br />SYSTEM <br />3 DIESEL <br />❑ 6 AVIATION GAS <br />n <br />® 2 PETROLEUM <br />a 80 EMPTY <br />® 1 PRODUCT <br />UNLEADED <br />1c MMGRADE UNLEADED <br />❑ 3 FIBERGLASS <br />4 GASAHOL <br />7 METHANOL <br />M85 <br />❑ 3 CHEMICAL PRODUCT <br />® 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED <br />fp6M TYT"4) <br />5 JET FUEL II�J-1 8 <br />99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.i) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br />Diesel <br />❑ 99 OTHER <br />c.A. S. #: N/A <br />® i RUBBER LINED <br />111. TANK CONSTRUCTION MARK ONE TEM ONLY IN BOXES A. B. AND C. AND ALL THAT APPLIES IN BOX D AND E <br />A. TYPE OF <br />® 1 DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br />SYSTEM <br />❑ 2 SINGLE WALL <br />❑ 4 SINGLE WALL IN A VAULT <br />❑ 99 OTHER <br />B. TANK <br />® i BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />❑ 8 100% METHANOL COMPATIBLE W/FRP <br />fp6M TYT"4) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />C. INTERIOR <br />® i RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />LINING OR <br />® 5 GLASS LINING <br />® 6 UNLINED <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />COATING <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES _ NO— N/A <br />D. EXTERIOR <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />CORROSION <br />PROTECTION <br />® 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />❑ 95 UNKNOWN <br />® 99 OTHER �St P 1 clad with ME <br />E SPILL AND OVERFILL, etc SPILL CONTAINMENT INSTALLED (YEAR) 1 993 OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />DROP TUBE YES NO STRIKER PLATE YES NO DISPENSER CONTAINMENT YES NO <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND, BOTH IF APPLICABLE * 90% Audible/Visual Alarm <br />A. SYSTEM TYPE <br />GO <br />i SUCTION <br />A U 2 PRESSURE A U <br />3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br />B. CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />A U 2 DOUBLE WALL A U <br />3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br />C. MATERIAL AND <br />CORROSION <br />PROTECTION <br />A U <br />A U <br />A U <br />i BARE STEEL <br />5 ALUMINUM <br />9 GALVANIZED STEEL <br />A U 2 STAINLESS STEEL A U <br />A U 6 CONCRETE A U <br />A U 10 CATHODIC PROTECTION <br />3 POLYVINYL CHLORIDE (PVC U 4 FIBERGLASS PIPE <br />7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br />A U 95 UNKNOWN A U 99 OTHER <br />D. LEAK DETECTION <br />❑ <br />1 11ECFIAlACAL LAKE LEAK Q <br />DETECTOA <br />2 tAaE 7KiHTlIESS a 3 cnNRnaT= MTEMTRML .❑ 4 ELECTRONIC LAK: O 5 AUTOLAnc PUMP Q 99 OTHER <br />TESTING MdATCRIKS LEAK DETECTOR SHUTDOWN <br />V. TANK LEAK DETECTION <br />❑ t VISUAL CHECK ❑ 2 MANUAL <br />❑ 3 VADOZEMONITORING 0 4 AUTOMATIC TANK ®5 GROUND MONITORING ❑ 6 ANNUALTESTING <br />® 7 MONITORING CONTINUICIUSINTERSTITIAL ❑ 8 SIR❑ 9 WEEKLY M NUAL ❑ 10 MONTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br />TAN <br />Vl. TANK CLOSURE INFORMATION (PERMANENT CLOSURE IN -mu <br />L <br />ESTIMATED DATE LAST USED (MO/DAYNR) 2. ESTIMATED OUANTITY OF 3. WAS TANK FILLED WITH YES E]NO <br />❑ <br />SUBSTANCE REMAINING GALLONS IINERT MATERIAL 7 <br />THI <br />FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AN9 TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORN <br />TANK OWNER'S NAME DATE <br />(PRINTEDBSMNATURE) C. Susi JacksonLz—:� <br />— t2_l21 t � <br />LOCAL AGENCY USE ONLY THE STATE LD. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION • FACILITY # TANK # <br />STATE I.D.4 m FM I I I-= <br />PERNT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />ECT <br />THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION - FORM A. UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br />SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br />FORM 8 (6,95) FORD NBA7 <br />/A <br />