My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 12
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 4:43:06 PM
Creation date
6/3/2020 9:55:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 12
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 12.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
472
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
09/22/05 11:05 FAX 925 422 2748 EPD / WGMG Q007 <br /> SWRCB,January 2002 FINAL DRAFT Page_6 of 7 <br /> 7. FILL RISER CONTAINWNTS UW TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sump(s) El <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> — <br /> Test Method Developed By: El Sump Manufacturer ❑Industry Standard aProfessional Engineer <br /> El Other(Specify) <br /> Test Method Used: 0 Pressure ❑Vacuum ❑Hydrostatic <br /> El Other(Specify <br /> Test Equipment Used: Equipment Resolution: <br /> Fill Sump# FBI Sum N Fill Sump# Fill Sump# <br /> Sump Diameter: <br /> Sump Depth: <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testing: <br /> Portion of Sump Tested <br /> Sump Material: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading N: <br /> -Test End Time: <br /> Final Reading(Rp) <br /> Test Duration: <br /> Change in Reading(RF-P%j): <br /> Pass/Fail Threshold or Criteria: <br /> pass <br /> QP Q� ElFait �01?7 <br /> 16tgeiiit ., . ". ,- lass <br /> Is there a sensor in the sump? UYes No YCS No LjYes No -Me—s '-- E114o <br /> Does the sensor alarm when <br /> either product or water is OYes E]No EINA E]Yes ONo ONA E]Yes E]No EINA OYes[]No EINA <br /> detected? <br /> Was sensor removed for testing? Yes No EINA Yes No FINA -E]Yes No EINA I QYes No EINA <br /> Was sensor property replaced and <br /> verified fimetional after testis B? I Oyes E]No DNA OYes ONo EINA OYes[]No EINA I Dyes El No EINA <br /> Comments—(Include information on repairs made prior to testing; and recommended follow upfor ailed tests) <br /> There is no Fill Riser Containment Sump. <br />
The URL can be used to link to this page
Your browser does not support the video tag.