COMPLIANCE INFO_FILE 12
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 4:43:06 PM
Creation date
6/3/2020 9:55:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 12
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 12.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
472
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> Site Address: Site 300-Bldg. 882, Corral Hollow Road, Tracy, CA 95376 Date: 9-14-2006 <br /> F. In-Tank Gauging/SIR Equipment: U Check this box if tank gauging is used only for inventory control. <br /> N Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> U Yes 0 No* Has all input wiring been inspected for proper entry and termination,including testing for ground fauR::::�� <br /> U Yes L3 No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> Ll Yes U No* Was accuracy of system product level readings tested? <br /> U Yes U No* Was accuracy of system water level readings tested.? <br /> U Yes E3 No* Were all probes reinstalled properly? <br /> Ll Yes Were all items on the equipment manufacturer's maintenance checklist completed? <br /> * In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors (LLD): E Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> El Yes Ll No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br /> 0 N/A (Check all that apply) Simulated leak rate: L33g.p.h.; LI0.1g.p.h; L30.2g.p.h. <br /> 0 Yes E3 No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> U Yes LJ No* Was the testing apparatus properly calibrated? <br /> U Yes U No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> Ll N/A <br /> Ll Yes Ll No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> U N/A <br /> Ll Yes U No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> U N/A or disconnected? <br /> U Yes U No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system <br /> Ll N/A malfunctions or fails a test? <br /> L3 Yes U No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> E3 N/A � <br /> U Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> * In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> Emergency generator,suction system. <br /> Page 3 of 3 03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.