My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 13
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 4:19:45 PM
Creation date
6/3/2020 9:55:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 13
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 13.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
393
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 FINAL DRAFT Page 4 of 7 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer ED Industry Stan ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Methal Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑other(specify) <br /> Test Equipment Used: Caldwell Sump Level Change Indicator Equi ent Resolution: 0.0025" <br /> Sump# Sump# Sump# Sump# <br /> 882-D lU2 <br /> Sump Diameter: 36.0" <br /> Sump Depth from Top of Tank: 36.0" <br /> Sump Material: FRP <br /> Height from Tank Top to Top of 17.75" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Top of <br /> 1,. 15.5" <br /> -O..,e,L Llectrical Penetration: <br /> Condition of sump prior to testing: Cl <br /> Depth of Sump Tested' 19.75" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both OYes❑No ONA ❑Yes❑No A ❑Yes❑No❑NA ❑Yes[]No❑NA <br /> product and water)?' <br /> Turbine shutdown response time: Suction System <br /> Is system programmed for fail-safe <br /> shutdown? ❑Yes❑No ONA ❑Yes❑No❑NA ❑Yes[]No❑NA ❑Yes❑No[INA <br /> Was fail-safe verified to be <br /> operational?* []Yes❑No ZNA ❑Yes❑No[INA ❑Yes❑No[:INA [—]Yes[:]No [:INA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 minutes <br /> test: <br /> Test Start Time: 12:25p <br /> Initial Reading(R): 19.75" <br /> Test End Time: 1:10p <br /> Final Reading(RF): 19.75" <br /> Test tion: 45 minutes <br /> Change in Reading(RF-Rr): 0.001 <br /> Pass/Fail Threshold or Criteria: 0.005" <br /> Test Result OPass ❑Fail ❑P ❑Fail Opass ❑Fail OPass, ❑Fail <br /> Was sensor removed fort g? Oyes❑No❑NA ❑Yes❑No❑NA ❑Yes®No❑NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and <br /> verified functional after to g? Yes❑No[-INA ®Yes❑No❑NA ❑Yes❑No❑NA ❑Yes[]No[INA <br /> Comments—(Include information on repairs made prior to testing,and recommended follow-up for failed tests.) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to ggy of the questions indicated with an <br /> asterisk(*)is"NO",then the entire sump should be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.