Laserfiche WebLink
MONI SYSTEM CERTIFI&TION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited.- Chapter 67, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Lawrence Livermore National Laboratory Site 300 Bldg. No.: B879 <br />Site Address: Corral Hollow Road City: Tracy Zip: 96376 <br />Facility Contact Person: Diane Griffin Contact Phone No.: (925) 423-1547 <br />Make/Model of Monitoring System: Gilbarco EMC Date of TestinglServicing: 8-1-2017 <br />B. Inventory of Equipment Tested/Certified <br />Check theappropriate boxes to indicate s cific equipment ins cted/serviced: <br />Tank ID: 879-TFUG01 Unleaded <br />Tank w: 879-TFUD0I Diesel <br />0 in -Tank Gauging Probe. Model: <br />MN 1 <br />ED in -Tank Gauging Probe. Model: Mag 1 <br />0 Annular Space or Vault Sensor. Model: <br />794390420 <br />Annular Space or Vault Sensor. Model: 794390420 <br />0 Piping Sump / Trench Sensor(s). Model: <br />794380-205 <br />Piping Sump / Trench Sensor(s). Model: 794380-205 <br />El Fill Sump Sensor(s). Model: <br />El Fill Sump Sensor(s). Model: <br />0 Mechanical Line Leak Detector. Model: <br />99LD-2000 <br />D Mechanical Line Leak Detector. Model: <br />El Electronic Line Leak Detector. Model: <br />0 Electronic Line Leak Detector. Model: <br />El Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />0 Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />[I In -Tank Gauging Probe. Model: <br />El In -Tank Gauging Probe. Model: <br />E) Annular Space or Vault Sensor. Model: <br />El Annular Space or Vault Sensor. Model: <br />C3 Piping Sump / Trench Sensor(s). Model: <br />M Piping Sump / Trench Sensor(s). Model: <br />El Fill Sump Sensor(s). Model: <br />n Fill Sump Sensor(s). Model: <br />0 Mechanical Line Leak Detector. Model: <br />0 Mechanical Line Leak Detector. Model: <br />n Electronic Line Leak Detector. Model: <br />El Electronic Line Leak Detector. Model: <br />0 Tank Overfill / High -Level Sensor. Model: <br />[3 Tank Overfill / High -Level Sensor. Model: <br />[I Other (specify equipment type and model in Section E on Page 2). <br />F1 Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ED: Unleaded I <br />Dispenser ED: <br />El Dispenser Containment Sensor(s). Model: <br />Bravo <br />El Dispenser Containment Sensor(s). eh <br />ED Shear Valve(s). <br />[I Shear Valve(s). <br />ED Dispenser Containment Float(s) and Chain(s). <br />F1 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: _ Unleaded 2 <br />Dispenser ID: <br />El Dispenser Containment Sensor(s). Model: <br />Bravo <br />[I Dispenser Containment Sensor(s). Model: <br />0 Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />El Shear Valve(s). <br />[:1 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ED: Diesel 3 <br />Dispenser ID: <br />F1 Dispenser Containment Sensor(s). Model: <br />Bravo <br />[I Dispenser Containment Sensor(s). Model: <br />Shear Valve(s). <br />[I Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />[3 Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equim nt. For any equipmenj capable of generating such <br />reports, I have also attached a copy of the report; (check all that apply): Ez"System set-up ;�gj_uarrn history report <br />Technician Name Brian Thornton Signature: . 7�7 — <br />Certification No.: A31662 License. No.: 724513 A, C-10, HAZ 1CC# 5024962 -UT <br />Testing Company Name: Thomton Environmental Construction, Inc. — Phone No.: (209) 834-0792 <br />Testing Company Address: PO Box 360833 Milpitas, CA 95036 Date of Testing/Servicing: 8-01-2017 <br />Page 1 of 3 <br />