CNI Man ufacturionstallation. Operation and Maintenar*Manual (IOM) <br />Applicable to Executive Order VR -1 04-D <br />Phase I EVR Equipment Installation Check List for <br />Installing Products per ARB Executive Order VRA 04-D (continued) <br />Yes/No <br />Initials <br />5. Fill Riser — Is the EMCO Wheaton Retail Al 100EVR Guardian <br />Overfill Prevention Valve installed with the correct EMCO Wheaton <br />O-ring securely in place and the flared end of tube on top of the riser? <br />(New installation and replacement O-ring are #569461.) <br />Note: The EMCO Wheaton Retail All 100EVR Guardian Overfill <br />Prevention Valve must be cut to the correct length and assembled per <br />manufacturer's instructions before installing into the 4 inch tank riser. <br />6. Are the Containment Assemblies installed onto the 4 inch tank risers <br />Yes/No <br />Initials <br />using a Fire Marshall approved thread sealing compound on the upper <br />male threads of the 4 inch riser pipe and torqued to: <br />• the indicated torque value from Table 1 and 2 for CON 1-31103 <br />and CON2-31103 containments; <br />• the indicated torque value from Table 3 and 4 for 205X-31103 and <br />214X-31103 containments? <br />7. Is the Jam Nut(s) installed in the lower set of threads of the Fil-Spil <br />Yes/No <br />Initials <br />oval flange (CON2-31103), or the bottom section of 205P-31103 or <br />214P-31103 containment, and torqued down on top of the drop tube <br />flare to 45 foot-pounds? <br />8. Have the 4 inch Containment Nipple(s) been cut to the correct <br />Yes/No <br />Initials <br />lengths and have a flat, square cut across the top of each end, as well <br />as the appropriate threads cut into the ends of each? <br />8.a. Have the 4 inch Containment Nipple(s) been installed into the <br />Yes/No <br />Initials <br />appropriate flanges using a Fire Marshall approved thread sealing <br />compound on the lower male threads of the 4 inch Containment Nipple <br />and torqued to 170-175 foot-pounds? <br />9. Are the appropriate Product and Vapor Swivel Adapters (p/n <br />Yes/No <br />Initials <br />A0030 -124S and A0076 -124S, or A0030-124 and A0076-124) <br />installed onto the 4 inch containment nipple(s) with the flat gaskets in <br />place, and torqued to 35 foot-pounds? <br />9.a. Are the Product Swivel Adapters (p/n A0030 -124S or A0030-124) <br />Yes/No <br />Initials <br />and Vapor Swivel Adapters (p/n A0076 -124S or A0076-124) set <br />screws installed with LocTite #222MS and torqued to 20 inch -pounds? <br />10. Are the CNI Mfg. Dust Caps (p/n 64 product, and 611 -VR -3 vapor) <br />Yes/No <br />Initials <br />and CNI Mfg. Gaskets (p/n 65) installed onto the appropriate Swivel <br />Adapters? <br />11. Are the drain valve(s) installed and bottomed out, then turned an <br />Yes/No <br />Initials <br />additional 360'legrees with the cap screwed back on until finger tight? <br />12. For CON1-31103 and CON2-31103 containments: Are the six <br />Yes/No <br />Initials <br />bolts for the 3 Piece Bellows Hold Down Clamp (p/n STP -33) torqued <br />to. 10 foot-pounds? <br />page. <br />Continued <br />on next <br />15627 ARROW HIGHWAY, IRWINDALE, CALIFORNIA 91706 <br />PHONE (626) 962-6646; Our OF STATE CALLS (800) 4CN1-MFG; FAX (626) 962-4854 11 <br />WEBSITE: WWW.CNI-MFG.com EMAIL: INFOO)CNI-MFG.COM <br />