Laserfiche WebLink
CNI ManufactuAstallation, Operation and MaintenanOManual (IOM) <br />Applicable to Executive Order VR -1 04-D <br />Figure A-10 <br />Installation Instructions for Emco Wheaton Swivel Fill (Product) Adapter <br />Retail A0030-124 <br />Base <br />Set Screw <br />(Total of 2) <br />30-124 <br />vel Fill <br />pter <br />Flat <br />Gasket <br />p/n <br />409628 <br />IMPORTANT: Do not use pipe thread sealant compound when installing the swivel product <br />adapter. These instructions are tailored to CNI Mfg. System and differ from the EMCO Wheaton <br />Retail system instructions. CNI Mfg. has a different torque assigned to the adapter as well as <br />requires the use of CNI Mfg. Swivel Adapter Installation/Removal Tool p/n EVRSYS106 for <br />installation and removal of the swivel adapters. <br />1) The top edge of the top riser nipple must be filed flat and square, with threads free of all <br />debris to insure a proper sealing surface between the riser nipple and the base of the <br />swivel product adapter. Verify squareness with T-square or bevel square. <br />2) Using a 5/32nd inch Allen® wrench, remove both set screws from the base of the swivel <br />product Adapter. <br />3) Before installing the swivel product adapter, verify that the flat gasket is properly in place. <br />Manually tighten the swivel product adapter onto the top riser nipple to avoid cross <br />threading. Using the CNI Mfg. Rotatable Adapter Tool p/n EVRSYS106, torque the swivel <br />product Adapter to 35 ft -lbs. <br />4) Apply a small amount of Loctite model® #222MS on both set screws. Reinstall the two set <br />screws and torque them to 20 inch pounds using the 5/32nd inch Allen® wrench head <br />adapter. <br />PREVENTATIVE MAINTENANCE <br />Static Torque Test <br />Annually verify the static torque of the swivel product Adapters by performing ARB test <br />procedure TP -201.1113 using CNI Mfg. Swivel Torque Test Tool p/n EVRSYS100 rather than <br />Phil-Tite Torque Test Tool p/n 6004 as specified in Section 5.2 of TP -201.1 B. The Phil-Tite <br />tool is not compatible with CNI Mfg. Dust caps. <br />If the swivel product Adapter fails to meet the test requirements, replace both 0 -rings using <br />EMCO Wheaton O-ring kit P/N 493995 and re -test. <br />Leak Tightness Integrity Test <br />Annually verify the leak tightness integrity of the swivel product Adapters while performing ARB <br />test procedures TP201.1 C or TP201.1 D on the drop tube(s). <br />If the swivel product Adapter fails, to meet the leak tightness integrity test requirements, replace both <br />O -rings using EMCO Wheaton O-ring kit P/N 493995 or flat gasket P/N 409628 and re -test <br />15627 ARROW HIGHWAY, IRWINDALE, CALIFORNIA 91706 <br />PHONE (626) 962-6646; Our OF STATE CALLS (800) 4CN1-MFG; FAX (626) 962-4854 65 <br />WEBSITE: WWW.CNI-MFG.coM EMAIL: INFO CI CNI-MFG.COM <br />