Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:42:38 AM
Creation date
6/3/2020 9:56:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5. <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X❑ Professional Engineer <br /> 0 Other (Specify) <br /> Test Method Used: F] Pressure ❑ Vacuum xI Hydrostatic <br /> Other (Spec) <br /> Test Equipment Used: VPLT Equipment Resolution: VPLT TO GPH <br /> ISuwmSump# 2 REG Sump# 1 REG Sump# 3 SUP Sump# 1 REG <br /> p <br /> 48" 48" 48" 4211 <br /> 43" 45" 45" 64"Material: FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 2911 24" 15" 4711 <br /> Highest Piping Pentration: <br /> Height from Tank Top to Lowest 1611 161, 1611 3011 <br /> Electrical Pentration: <br /> Condition of sump prior to testing: GOOD GOOD GOOD GOOD <br /> Portion of Sump Tested: 1 3111 2611 17" 4911 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both —71 XJYes❑NoON EYes F]NoON MYes ONo[_ Yes❑No�T <br /> product and water)?* <br /> Turbine shutdown response time: 2-5 S E C 2-5 SEC 2-5 SEC 2-5 S EC <br /> Is system programmed for fail-safe ❑Yes ❑ o ❑ <br /> Yes No❑N N X � X X <br /> shutdown?* <br /> Was fail-safe verified to be ❑ ❑ ❑ ❑ ❑ ❑ ❑ [:] <br /> operational?* X Yes N N X Yes N N X Yes N N X Yes No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5MIN 5MIN 5MIN 5MIN <br /> test: <br /> Test Start Time: 14 :08 11:24 10:21 12 :24 <br /> Initial Reading(R1): 7.713 10.236 6.021 4.573 <br /> Test End Time: 14:38 11:54 10:51 12 :54 <br /> Final Reading(RF): 7.713 10.132 5 .627 4.573 <br /> Test Duration: 3 0MIN 3 0MIN 3 0MIN 3 0MIN <br /> Change inReading(RF-R1 ): .000gph .008gph .03gph .000gph <br /> Pass/Fail Threshold or Criteria: .05gph .05gph .05gph .05gph <br /> Was sensor removed for testing? X YesoNoE]NA�YesE]NoE]NA 2 Yes N NA EYes D_NoF]N <br /> Was sensor properly replaced and NA ❑Ye�N�NA ❑Yes0 N�NAo Yes❑ <br /> N <br /> verified functional after testing? ❑Ye N X <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the sump is not tested,specify how much was tested.If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />