COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:16:11 AM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.so.gov.org/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 3 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 08/22/11 <br />Facility Address: 3250 Hammer Lane, Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />Routine and Monitoring System Certification Underground Storage Tank inspection - AMENDED report <br />7. An alarm log was not found on site for the following alarms: L6 - 92 turbine sump - fuel alarm - <br />8/9/11, 6/23/11, 4/18/11, 2/17/11, and 12/18/10; L5 - 87 master turbine sump - fuel alarm - 6/23/11; L4 - <br />87 siphon piping sump - fuel alarm - 7/23/11, 7/6/11, 6/23/11. Keep a record of the date, identification, <br />corrective action, and service technician receipt (if applicable) for each alarm. These records shall be <br />kept on site for at least 3 years. Immediately locate and maintain the alarm logs on site and submit <br />copies to the EHD by September 22, 2011. <br />12 & 16. The vapor condensate trap suction line secondary containment pipe was plugged where it <br />drains into the 87 turbine sump. The testing technician removed the plug during the inspection. <br />18. The 87 siphon and 91 spill containers failed when tested. All spill containers shall have a minimum <br />capacity of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br />The new spill containers passed the capacity and tightness tests under permit (SR0063300) on the day <br />of the inspection. <br />23a. A new designated operator, Steve Zwahlen, was hired in August 2010 and notification was not <br />provided to the EHD within 30 days of the change. A new designated operator, James Flowers, was <br />hired in April 2011 and notification was not provided to the EHD within 30 days of the change. Any <br />changes shall be reported to the EHD with 30 days. Submit notification to the EHD identifying all the <br />designated operators for this facility by September 22, 2011. <br />23c. The designated operator failed to check and note the correct test dates for the secondary <br />containment test, spill container test and monitoring system certification on the 8/10 through 7/11 <br />designated operator monthly inspection reports. The correct dates are: 8-22-11 for the monitoring <br />system certification and spill container test, and 4-21-09 for the secondary containment test. During the <br />monthly inspection, the designated operator shall check that all required testing and maintenance for the <br />UST system have been completed and document the dates they were done. Ensure that designated <br />operators performing monthly inspections at this facility are including all of the required information on <br />the reports. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT HUS CURRENT HOURLY RATE. <br />EHD Inspector: <br />vt <br />Rece ed B Title: <br />`�dyl e i <br />EHD 23-0 03 Rev 07/12/11 vV U CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.