My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2005-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:36:01 PM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2010
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232397_1777 W YOSEMITE_2005-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
465
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page q of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: 0 Sump Manufacturer 0 industry Standard X Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used:Caldwell Level Change Indicator Equipment Resolution: .002 <br /> UZZISM <br /> Sump#I Sump# Sump# Sump# <br /> Sump <br /> ump Diameter: 4391 <br /> Sump Depth: 3799 <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of Vent 19" <br /> Highest Piping Penetration: Product 16" <br /> Height from Tank Top to Lowest 13" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry <br /> Portion of Sump Tested' Water Level 19" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Yes No X NA Yes No NA Yes No NA Yes No NA <br /> product and water)?. <br /> Turbine shutdown response time N/A <br /> Is system programmed for fail-safe Yes No X NA Yes No NA Yes No NA Yes No NA <br /> shutdown?* <br /> Was fail-safe verified to be Yes No X NA Yes No NA Yes No NA Yes No NA <br /> operational?* <br /> Wait time between applying water 10 Minutes <br /> and start!ng test: <br /> Test Start Time: 8:45 <br /> Initial Reading(Rj): .001 <br /> Test End Time: 9:15 <br /> Final Reading(RF): .001 <br /> Test Duration: 30 Minutes <br /> Change in Reading(RF-RO: .000 <br /> Pass/Fail Threshold or Criteria: .005130 Minutes <br /> Test Result: X Pass 0 Fail Pass 0 Fail X Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? X Yes 0 No 0 NA Yes 0 No 0 NA Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> Was sensor properly replaced and XYes ONo [INA Yes 0 No 0 NA Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> verified functional after testing? <br /> Comments—(indude information on repairs made prior to testing, and recommended follow-up forLailed tests) <br /> No Turbin! System is not Conventional Suction, or Safe Suction. <br /> System is equipped with Swing Check Valves at Tank Piping Sump, and Electric Pump Motors, <br /> that push product, from Tank Piping Sump,to Day Tank,under pressure. <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to M of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SVrRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.