My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2005-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:36:01 PM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2010
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232397_1777 W YOSEMITE_2005-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
465
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page t of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ❑Industry StandardProfessional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: C4 tAue, C x., .. ; m to A-C r Equipment Resolution: d <br /> Sump# L Sump# Sump# Sump# <br /> Sump Diameter: 4-3 xi <br /> Sump Depth: 37 <br /> Sump Material: v b S S <br /> Height from Tank Top to Top of 4-01A4- 'Let t <br /> Hi est Piping Penetration: r <br /> o d��� t <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: j <br /> Condition of sump prior to testing: --0 !n <br /> Portion of Sump Tested' W 1%4eAr L+1#_AL, tt <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No )(NA ❑Yes ❑NA ❑Yes N ❑NA ❑ es ❑ o ❑NA <br /> product and water)?* <br /> Turbine shutdown response time 0 1 A. <br /> Is system programmed for fail-safe <br /> shutdown?* ❑Yes ❑No XNA ❑Yes ❑ o ❑NA ❑Yes ❑ o ❑NA ❑ jNo ❑NA <br /> Was fail-safe verified to be a <br /> o erational?* ❑Yes ❑No j<NA ❑Yes ❑*o ❑NA ❑Yes ❑ ❑NA ❑Y /El No ❑NA <br /> Wait time betwee ing <br /> pressure/vacu water d starting k <br /> test: ( ort K u 4--eS <br /> Test Start Time: _ It <br /> Initial Reading(111): , v u <br /> Test End Time: <br /> Final Reading(RF): t)t) <br /> Test Duration: 3 t S <br /> Change in Reading(RF-Rj): <br /> Pass/Fail Threshold or Criteria: ®� 3d t„; <br /> b <br /> Test Result: <br /> Pass 11 Fail Pass ❑Fai Pass ❑F it Pass Fail <br /> Was sensor removed for testing? Yes ❑No ❑NA Yes ❑No ❑N Cii'Yes ❑No ❑ A Yes ❑No NA <br /> Was sensor property replaced and t <br /> verified functional after testing? 4'es ❑No ❑NA Yes ❑No ❑NA Yes ❑No ❑ A ❑Yes ❑No ❑ A <br /> 1 <br /> Comments—(include information on repairs made prior to testing and recommended follow up for ailed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to 4gy of the questions indicated with an <br /> asterisk(*) is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.