Laserfiche WebLink
U FLED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN-(Page 1 of 2) <br /> TYPE OF ACTION 1.NEW PLAN ❑ 2 CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE 1.MONITORING IS IDENTICAL,FOR ALL UST.,AT THIS FACILI'T'Y. 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY•THE FOLLOWING U'S'T'SYSTENI(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) t. <br /> BUSINIESS NAME(Same as l:acdity Vame or DBA) 3' <br /> K�AhCfe C int fA�+ws•✓('� <br /> r <br /> BUSINESS SITE ADDRESS 103. 1 CITY tea <br /> X777 iM-%--4Tt4_A <br /> I . EQUIPMENT TEST G AND PREVENTIVEIAC <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detects,:s,etc.)must be performed at the frequency specified <br /> by the equipment manufacturaars'instructions,or annually,whichever is more frequent.Such work must be performed by qualified personnel.[23 CCR§2632,263k 2638.26411 <br /> 490-3a. <br /> MONITORING EQUIPMENT IS SERVICED L ANNUALLY ❑ 99.OTHER(Specitv): 490-31 <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAMMAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED 123 CCR 22632,2('31] g40-4. <br /> IV. TANK MONITORING IS PERFORMEDUSING THE FOLLOWING (S) a heel`,n <br /> Q 1.CONTINUOUS ELECTRONIC TANK N10NITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490.5. <br /> WITH AUDIBLEAND VISUAL ALARMS.123 CCR§2632,26341 <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY Q b.LIQUID FILLED ❑ c.PRFSSUR17.FD ❑ d.UNDER VACUUM 4906. <br /> PANEL MAN'U'FAC;I'URER: iD•,,�nr, L„,r„®.,,ta 490-7. MODEL#: 490-8. <br /> LEAK SENSOR MANUFACTURER: 490-9- MODFL#(S): 490-10. <br /> .......... <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§26431 490 11. <br /> PANEL MANUFACTURER: 490-12" MODEL#: 490-13. <br /> ]INT-T INK PROBE M'LANNUFACTUT.ER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c•WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17.400-18. <br /> PROGRA]bRIED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ e.OTIIER(Specify): 499-19. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION 123 CCR 62646.11 490-20. <br /> ❑ 4.WEEKLY MANUAL,TANK GAUGING(MTG)[23 CCR P6451 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 490 22. 1 <br /> _ __ -- -- ...__._._._._..._ <br /> ....... _._.._.. _ __.......... . ....__._...... .._.. -- .. <br /> ❑ 5.TAINl'EGRITY TESTING PER[23 CCR§2643.11 ago-TANK <br /> 490-20-. <br /> TIKST FREQUENCY: ❑ a.ANNUALLY ❑ h BIENNIALLY ❑ c.O'T'HER(Specify): 49490- <br /> _.. ...... -9__._..... <br /> 99.OTHER(Specify): 490�6 <br /> ❑ ( P - ): 1 y:.t✓�i. � �-'i.�. 0-90-27. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING ET (S) (Check all <br /> thud apply) <br /> 1.CONTINUOUS MOivIT`ORING OF PIPF/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS- 49x28' <br /> 123 CCR SECONDARY CONTAINMENTIS: a.DRY ❑ b.LIQUID I-ILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUMS 490-29' <br /> §"b35J <br /> PANEL MANUFACTURER: 1 :+;G.+•' L+.: +i; 4901W MODEL#: 490-31. <br /> LEAK SENSOR MANUFACTURER: iZ�,.+ ,.► 490-30-. ;,,IODEL#(S): 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e...TURBINE)SHUTDOWN. ❑ a.YES ® b.NO 490-34' <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a-YES JZ b.NO 490-35. <br /> .. _ _. - - ...... _.- --- -- - -- - - <br /> ❑ 2 MfECHA]VICr1L LINE LEAIa DETECTOR(MELD)THAT RO[J'fINELY PF.RFORsViS 3-0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 49a3o. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.123 CCR§26361 <br /> MLLD MANUFACTURER(S): 490-37. MODEL#(S): 490.38. <br /> _. ...... 490-39. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.123 CCR§26361 <br /> ELLD MANUFACTURFR(S): 49440. MODEL tl(S): 490-41. <br /> PROGRAMMED INT LINE LEAK TEST: ❑ a.NIINIMUN4 MONTHLY 0.2 g.p.h. ❑ b.MIN MU.M ANNUAL 0.1 g.p.h. 49x42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 49043. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-44. <br /> ❑ 4.PIPE INTEGRITY TESTING. 490-45' <br /> _ . _ - 0-90-0-6. <br /> TEST FREQUENCY: a.ANNUALLY b.EVERY 3 YEARS c.OTHER(S ecify) 0-80-47. <br /> ❑ 5.VISUAL PIPE MONITORING.... 490-48. <br /> FREQUFNCY: [Z a.DAILY ❑ b.WEEKLY ❑ c.r.SIN.MONTHLY&EACH TIME SYSTEM OPERATED' 490-49. <br /> _......__..-._"Alluwer!fur newuturir. _f wrluriul ewer8e,ay.8areratur fuel Iutw nJy pet HSC?i25281.5(bx3).- <br /> ❑ 49G-50.6.SUC11ON PIPING MEET'S EXEMP'lION CRITERIA.123CCR§2636(a)(3)l <br /> ---... ........ ---. ...._.....__.._...__....__._......... -._....... ... - __.._.................. 1 <br /> [� 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO TI IE TANK SYSTEM. 4°s' <br /> _.-._..... ....... ........-.. _. ...... ._ ......._ .. _.. _.._.._...._...._........................ -._...._._ . ._ _ _._...._._ . . ....... <br /> ❑ 99.OTHER(Spcoif) 490-53. . <br /> ItPCF UST-D(1=007)-114 www.uniducs.org <br />