My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2005-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:36:01 PM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2010
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232397_1777 W YOSEMITE_2005-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
465
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 3 . <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: F1 Sump Manufacturer El Industry Standard Professional Engineer <br /> El Other (Specify) <br /> Test Method Used: F] Pressure ❑ Vacuum Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: vp1t Equipment Resolution: +-.002" <br /> Sump# 1 DIE Sump# Sump# Sump# <br /> Sump Diameter: 4811 <br /> Sump Depth: 4811 <br /> NONE= <br /> Sump Material: fiberglass <br /> Height from Tank Top to Top of 1911 <br /> Highest Piping Pentration: <br /> Height from Tank Top to Lowest 171 <br /> Electrical Pentration: <br /> Condition of sump prior to testing: good <br /> Portion of Sump Tested: 1 21 <br /> Does turbine shut down when <br /> sump sensor detects liquid(bothA IYes DNo❑N Yes❑No❑N ❑Yes F—]No❑N []Yes[]Not <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec <br /> Is system programmed for fail-safe � ❑ ❑ � ❑ � ❑ ❑ �„T <br /> shutdown?* Yes N N Yes N N Yes N N Yes No <br /> Was fail-safe verified to be ❑ ❑ ❑ � n [ ] T <br /> ❑ <br /> operational?* X Yes N N ❑Yes N N X Yes N N X Yes� No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min <br /> test: <br /> Test Start Time: 10:10 <br /> Initial Reading(RI): 0 <br /> Test End Time: 10:40 <br /> Final Reading(RF): -.000811 <br /> Test Duration: 3 Omin <br /> Change in Reading(R F-RI ): -.00081, <br /> Pass/Fail Threshold or Criteria: +- .00211 <br /> sm <br /> Was sensor removed for testing? XYes❑No❑NA❑Yes❑No[:]NA❑Yes❑No❑NA❑Yes 1:1 [:]Nd <br /> Was sensor properly replaced and � ❑ � ❑ � ❑ ❑ <br /> verified functional after testing? Ye N NA Ye N NA Ye N NA Yes N <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the sump is not tested,specify how much was tested.If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.