Laserfiche WebLink
-EQXX.MH11766 - Control, rtoring and Auxiliary Equipment 10 Pagel of 4 <br />Page Bottom <br />EQXX.M H 11766 <br />Control, Monitoring and Auxiliary Equipment <br />Control, Monitoring and Auxiliary Equipment <br />See General Information for Control Monitoring and Auxiliary Eguioment <br />VEEDER-ROOT CO MH11766 <br />125 POWDER FOREST DR <br />PO BOX 2003 <br />SIMSBURY, CT 06070-7684 USA <br />Wireless line leak detectors, Form Nos. 849470-001, -002, -003, -005, PA0263000100, -002, -003. <br />Electronic meter register systems, designated EMR3 consisting of one or two electronic meter registers Form No. 8456 followed by 9, followed <br />by 2 thru 9, followed by one or more numbers and interconnect box Form No. 8458 followed by 93, followed by 0, 1 or 2, followed by 0 or 1, <br />followed by 1 or 2. For use with peripheral equipment as specified by the installation instructions. <br />Associated Apparatus, Nonhazardous location, Inventory Measurement System, designated TLS -IB, consisting of Form No. 846690-180, <br />-280, -380 or -480 control unit for use with up to eight probes, Form Nos. 8462, 8463, 8563 or 8570 and/or Mag Flex Probe model 8895 and/or <br />Mag Plusl, May be used with an I.S. Circuit Protector, Part Nos. 848190-001, -002 and -003 intrinsically safe for use in Class I, Div. 1, Group D <br />when installed as per Control Drawing Number 331940-014. May be used with peripheral equipment as specified by the installation instructions. <br />May be provided with an overfill alarm Form No. 790091-001 with or without an acknowledgement switch Form No. 790095-001. <br />Associated Apparatus, Nonhazardous location, Inventory Measurement System, designated TLS -50, consisting of Form No. 846990-060, <br />-160, -230 or -260 control unit for use with up to six probes, Form Nos. 8462, 8463, 8563 or 8570 or Mag Plusl, May be used with an I.S. Circuit <br />Protector, Part Nos. 848190-001, -002 and -003 intrinsically safe for use in Class I, Div. 1, Group D when installed as per Control Drawing <br />Number 331940-014. May be used with peripheral equipment as specified in the installation instructions. May be provided with an overfill alarm <br />Form No. 790091-001 with or without an acknowledgement switch Form No. 790095-001. <br />Associated Apparatus, Nonhazardous location, Inventory Measurement System, designated TLS-HLD, consisting of Form No. 846990- <br />360 control unit for use with up to six probes, Form Nos. 8462, 8463, 8563 or 8570 or Mag Plusl, May be used with an I.S. Circuit Protector, Part <br />Nos. 848190-001, -002 and -003 intrinsically safe for use in Class I, Div. 1, Group D when installed as per Control Drawing Number 331940-014. <br />May be used with peripheral equipment as specified in the installation instructions. May be provided with an overfill alarm Form No. 790091-001 <br />with or without an acknowledgement switch Form No. 790095-001. <br />Associated Apparatus, Nonhazardous locations, Inventory Measurement System, designated TLS -2, consisting of Form No. 856090-X6Y, <br />where X and Y are any character or 856092-060 control unit for use with up to six probes, Form Nos. 8462, 8463, 8563 or 8570 or Mag Plusl, <br />May be used with an I.S. Circuit Protector, Part Nos. 848190-001, -002 and -003 intrinsically safe for use in Class I, Div. 1, Group D, when <br />installed as per control drawing number 331940-014 . May be used with peripheral equipment as specified in the installation instructions. May be <br />provided with overfill alarm Form No. 790091-001 with or without an acknowledgment switch Form No. 790095-001. <br />Associated Apparatus, Nonhazardous location, Inventory Measurement System, designated TLS -300 consisting of control unit, Form No. <br />84859X -XXX where X can be any character may be connected to thirty-two intrinsically safe sensors or probes. May also be provided with overfill <br />alarm Form No. 790091-001 with or without acknowledgement switch Form No. 790095-001. The probes and sensors have been evaluated for <br />use in Class I, Div. 1, Group D hazardous locations when connected in accordance with control drawing number 331940-013. The following <br />probes and sensors are suitable for this system: <br />Magnetostrictive probes, Basic Form Nos. 8462, 8463, 8563, 8570; <br />Liquid or Vapor Sensors, Basic Form Nos. 7943 with or without 80 or 90 maybe be followed by three characters; <br />2 to 1 Sensor Input Boxes, Form No. 857390-102; <br />Oil/Water Separator Sensor, Basic Form No. 7946; <br />UL Listed Submersible Pump, Models PC or PAGC; or Mag Plusl. <br />Liquid level gauge/leak detection system, designated TLS -450/8600. Associated Apparatus, non -hazardous location, liquid level <br />gauge/leak detector control unit, Form No. 8600, followed by 90, followed by 1 followed by 00, provides intrinsically circuits for use in Class I, <br />Div. 1, Group D and Class I, Zone 0, Group IIA Hazardous Locations, may be used with up to 16 intrinsically safe probes/sensors per USM <br />Module when installed in accordance with Control Drawing 331940-008. Suitable Intrinsically Safe Devices for use in Class I, Div. 1, Group D <br />are 2 to 1 Sensor Input Box - Form No. 857390-102 only for use with Sensor Form Nos. Sump - 7943XX-20X, Position Sensitive - 7943XX-323 <br />and Hydrostatic - 7943XX-30X or; Temperature Sensor Form No. 794380-210 or; Magnetostrictive Probes - Form No. 84639X -XXX, 85639X -XXX; <br />or Mag Sump Sensor - Form No. 857080 -XXX; or Vapor Flow Meter Form Nos. 331847 -XXX, or 332374 -XXX; or ISD Pressure Sensor Form No. <br />861190 -XXX; or Digital Pressure Line Leak - Form No.8590XX-XXX; or Mag Plusl Form Nos. 88959X -XXX; or Senosr Form Nos. - Discriminating <br />Interstitial 79438X-343, Microsensor - 79438X-344; or Sensor Form Nos. Sump - 7943XX-20X, Hydrostatic - 7943XX-30X; or Dispenser Pan <br />7943XX-32X, Position Sensitive - 7943XX-323, 7943XX-333, Containment Sump 794380-35X, Interstitial 7943XX-40X; Steel Tank 7943XX-4X0; <br />or Oil/Water separator sensors - Form No. 7946XX-XXX; or CSTP Liquid Switch, UL Listed Veeder-Root Submersible Pump Basic Models PC or <br />PAGC; or Vacuum Sensor Form No. 332175 -XXX; or Ground Water Sensors - Form No. 7943XX-62X; or Vapor Sensor - Form No. 7943XX-70X; or <br />Overfill alarm, Form No. 790091-001, with or without an acknowledgement switch Form No. 790095-001; or USM Modules, Form No. 865090- <br />100, -101, -102, -103, or -104, up to four provided, module provides intrinsically safe circuits for combinations described above; or I/O Modules, <br />Form No. 865090-200, -210, -211, -212, -220, -221, -222 or -230, up to four provided, module provides external contact closure circuits; or <br />http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=E... 7/17/2017 <br />