EQXX.MH11766 - Control, Nj&itoring and Auxiliary Equipment Page 2 of 4
<br />W is
<br />Communication Modules, Form Nos. 865090-301, -302, -303, -304, -330, -331, -332, -333, -339, -340, -341, or -401; or I.S. Circuit Protector,
<br />Part Nos. 848190-001, -002 and -003 may be used with peripheral equipment as specified in the installation instructions.
<br />Associated Apparatus, Non -Hazardous Location, Inventory Measurement System, Control unit Model TLS -RF, Form No. 332242-001,
<br />-002 for use in non -hazardous locations, provides intrinsically safe outputs for use in Class I, Div. 1, Group D when used and installed as specified
<br />in the Installation Manual, 577013-839 or 577013-964. May also be connected to non -hazardous locations peripheral equipment as specified in
<br />the installation manuals.
<br />Intrinsically Safe Apparatus, Class I, Div. 1, Group D, Inventory Measurement System, Battery Box, Part Number 332425-001 only for
<br />connection to the intrinsically safe transmitter, Part Number 332235-001, which is in turn only for connection to one:
<br />Intrinsically safe probe, Form No. 84739, 85639, 84689, 84629 or 84639 all followed by 0 or 1, followed by 0, 1, 2, 3, 4, 5, 6 or 7, followed by 00
<br />to 17 inclusive or 99; or Form No. 857080 followed by 1 or 2, followed by 0, 1, or 2, followed by 1 or 2; or
<br />CCVP - Form No. 861290 -XXX; or
<br />ISD Flow Meter and Balanced Flowmeter - Part Nos. 331847-001, 331847-002, 332374-001 and 332374-002;
<br />ISD Vapor Pressure Sensor - Part No. 86119X -XXX; or Mag Plusl.
<br />I.S. Circuit Protector, Part Nos. 848190-001, -002 and -003.
<br />All suitable for use in Class I, Group D when used and installed as specified in the Control Drawing 331940-012.
<br />Liquid -level Gauge Accessory, Inventory Measurement System, Battery Box, Part No. 332425-001, Intrinsically Safe Devices, Class I,
<br />Div. 1, Group D only for connection to the Model Mag XL -RF intrinsically safe transmitter, Part No. 333062 -XXX (where XXX represent
<br />alphanumeric characters unrelated to safety certification). The Mag XL -RF intrinsically safe transmitter provides intrinsically safe outputs for use
<br />in Class I Group D as specified in Control Drawing, 331940-009.
<br />Associated Apparatus, Nonhazardous location, Inventory Measurement System, designated TLS -350 or TLS -350 -PC or TLS -3501,
<br />consisting of control unit Form No. 84709 followed by 0, 5 or 7, followed by 0, 3, 4, 5 or 6, followed by 0 or 2, suffixed 2 or 4; or designated TLS -
<br />350R or Simplicity consisting of control unit Form No. 84829 followed by 0, 1, 2, 3, or 5, followed by 0 or 1, followed by 0 or 2, followed by 2 or 4
<br />or designated 4000 consisting of control unit Form No. 848390, followed by 5 or 8, followed by 00; May be provided with: Overfill Alarm Form No.
<br />790091-001 with or without an Acknowledgement Switch Form No. 790095-001; Remote Display Unit, Form No. 8478, followed by 8 or 9,
<br />followed by 0, followed by 1 or 2, followed by 1 or 2, followed by 1 or 2. Form No. 847090-1 followed by 0, 1 or 2, followed by 2; The control unit
<br />may be provided with a combination of Plug-in Modules Form Nos. 847490-001, -100, -101, -102, -103, -104, -105, -106, -109, -110, -111,
<br />-202, -204, -206, -207, -208, -209, -210, -300, -301, -302, -303, -304, -305, -306, -309, -315, -316, -317, -326, -327, -340, -350, -360, -370,
<br />-380, -400, -401, -410, -420, -430, -431, -480 or Form Nos. 329359-001, 329360-001, 332250-001 (only one can be provided), or 332451-001.
<br />Form No. 847090-1, control unit may additionally be provided with Form Nos. 847490 107 or -108 plug-in modules. Advanced Application Module
<br />Form No. 849090 followed by 5 or 8, followed by 00 to 16 inclusive and up to 16 liquid sensors; Form No. 7943 followed by 8 or 9, followed by 0,
<br />followed by -205, -301, -302, -333, -401, -404, -407, -409 or -420; TLS -RF Console, up to four may be connected to intrinsically safe field wiring
<br />terminals but cannot be placed in the hazardous location. TLS -350 Consoles may connect up to 64 of the intrinsically safe apparatus below. These
<br />devices have been evaluated for use in Class I, Div. 1, Group D hazardous locations when connected to the above in accordance control drawing
<br />number 331940-011. The following probes and sensors are suitable for this system:
<br />Magnetostrictive probes, Basic Form Nos. 8462, 8463, 8563, 8570;
<br />Liquid or Vapor Sensors, Basic Form Nos. 7943 with or without 80 or 90 maybe be followed by three characters;
<br />CCVP, Form No. 861290 -XXX;
<br />ISD Flow Meter, Part No. 331847 -XXX or 332374 -XXX;
<br />Vapor Pressure Sensor, Part No. 331946 -XXX or basic Form No. 8611;
<br />Pressure Line Leak Detectors (PLLD), Basic Form Nos. 8484;
<br />Vacuum Sensors, Form No. 332175 -XXX;
<br />2 to 1 Sensor Input Boxes, Form No. 857390-102;
<br />Oil/Water Separator Sensor, Basic Fom No. 7946;
<br />UL Listed Submersible Pump, Models PC or PAGC; Mag Flex Probe Model 8895.
<br />I.S. Circuit Protector, Part Nos. 848190-001, -002 and -003.
<br />Liquid level gauge/leak detection system, designated 8601. Associated Apparatus, non -hazardous location, liquid level gauge/leak
<br />detector control unit, Form No. 86019X -XXX, where X represents any alphanumeric character. Provides intrinsically safe circuits for use in Class I,
<br />Division 1, Group D, and Class I, Zone 0, Group IIA Hazardous Locations; may be used with up to 12 intrinsically safe probes/sensors when
<br />installed in accordance with Control Drawing 331940-018. Suitable Intrinsically Safe Devices for use in Class I, Div. 1, Group D are 2 to i
<br />Sensor Input Box - Form No. 857390-102 only for use with Sump, Position Sensitive and Hydrostatic Sensors, Form No. 794380 followed
<br />by -208, -209, -301, -304, -323; or Magnetostrictive probes, Form No. 84639, followed by 0 to 9, followed by 0 to 9, followed by 00 to 99 or
<br />Form No. 85639, followed by 0 or 1, followed by 0 to 9, followed by 00 to 99 or Form No. 857080or Form No. 846291, followed by -100 through
<br />-199 or ISD Flow Meter Form No. 331847-001, 331847-002, 332374-001 or 332374-002 or ISD Pressure Sensor Form No. 86119X -XXX or
<br />Digital pressure line leak, Form No. 332681 -XXX; or Discriminating dispenser pan, containment pump, interstitial sump, hydrostatic
<br />and position sensitive sensors, Form No. 794380 followed by -208, -209, -301, -302, -303 -304, -322, -323, -333, -343, -344, -345, -352,
<br />-430 or Form Nos. 794390, followed by -401, -404, -407, -409, -420, -449, -460; or Temperature Sensor Form No. 794380-210; or CSTP Liquid
<br />Switch, UL Listed Veeder-Root Submersible Pump Basic Models PC or PAGC; or Vapor sensor, Form No. 794390-700 or Solid state
<br />discriminating sensors, Form No. 794380, followed by -320, -350, -360, -361, -362; or Solid state dispenser pan and containment sump
<br />sensors, Form No. 794380, followed by -321, -351; or Ground water sensors, Form No. 794380, followed by -621, -622, -624; or Vacuum
<br />Sensor, Form No. 332175 -XXX; or Oil Water Separator Sensors - Form Nos. 794690 followed by -000 to -999; or Mag Plusl; May be used with
<br />an I.S. Circuit Protector, Part Nos. 848190-001, -002 and -003. The control unit may also be provided with the following equipment for use in
<br />non -hazardous locations: Overfill alarm, Form No. 790091-001, with or without an acknowledgement switch Form No. 790095-001 or
<br />Communication Modules, Form Nos. 865090-301, -302, -303, -304, -330, -331, -332, -333, -339, -340, -341 or -401 may be used with
<br />peripheral equipment as specified in the installation instructions.
<br />http://database.ul.comlcgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=E... 7/17/2017
<br />
|