Laserfiche WebLink
•EQXX.MH11766 - Control, itoring and Auxiliary Equipment Page 3 of 4 <br />W is <br />Liquid level gauge/ leak detection system, designated 8603. Associated Apparatus, non -hazardous location, liquid level gauge/leak <br />detector control unit, Form No. 86039X -XXX, where X represents any alphanumeric character. Provides intrinsically safe circuits for use in Class I, <br />Division 1, Group D Hazardous Locations; may be used with up to 16 intrinsically safe probes/sensors per USM Module when installed in <br />accordance with Control Drawing 331940-019. Suitable Intrinsically Safe Devices, for use in Class I, Division 1, Group D are 2 to 1 Sensor <br />Input Box - Form No. 857390-102 only for use with Sump, Position Sensitive and Hydrostatic Sensors, Form Nos. 794380 followed by <br />-208, -209, -301, -304, -323, -333; or Magnetostrictive Probes - Form No. 84639 followed by 0 to 9, followed by 0 to 9, followed by 00 to 99 <br />or Form No. 85639, followed by 0 or 1, followed by 0 to 9, followed by 00 to 99, or Form No. 857080, or Form No. 846291 followed by -100 <br />through -199; or Discriminating Dispenser Pan, Containment Pump, Interstitial Sump, Hydrostatic and Position Sensitive Sensors - <br />Form Nos. 794380 followed by -208, -209, -301, -303 -304, -322, -323, -333, -343, -344, -345, -352, -430 or Form Nos. 794390 followed by <br />-401, -404, -407, -409, -420, -460; or Temperature Sensor Form No. 794380-210; or CSTP Liquid Switch, UL Listed Veeder-Root Submersible <br />Pump Basic Models PC or PAGC; or Vapor Sensor - Form No. 794390-700; or Solid State Discriminating Sensors - Form Nos. 794380 <br />followed by -320, -350, -360, -361, -362; or Solid State Dispenser Pan and Containment Sump Sensors - Form Nos. 794380 followed by <br />-321, -351; or Ground Water Sensors - Form No. 794380 followed by -621, -622, -624; or Vacuum Sensor, Form No. 332175 -XXX; or Oil <br />Water Separator Sensors - Form Nos. 794690 followed by -000 to -999; or Digital Pressure Line Leak - Form No. 85908X -XXX; or Mag Plusi; <br />May be used with an I.S. Circuit Protector, Part Nos. 848190-001, -002 and -003. The control unit may also be provided with the following <br />equipment for use in non -hazardous locations: Overfill alarm, Form No. 790091-001, with or without an acknowledgement switch Form No. <br />790095-001; or USM Modules, Form No. 865090-100, -101, -102, -103 or -104, up to four provided, module provides intrinsically safe circuits <br />for combinations described above or I/O Modules, Form No. 865090-200, -210, -211, -212, -220, -221, or -222, up to four provided. <br />Class I, Division 1, Group D and Class I, Zone 0, AEx is IIA T4 Hazardous Locations. <br />Liquid level probes, intrinsically safe for use in Class I, Div. 1, Group D and Class I Zone 0 Group IIA; hazardous locations when installed in <br />accordance with installation manual 577013-744, Form Nos. 84539, 84639, 84629, 85639 or 84739 followed by 0 or 1, followed by -XXX, where <br />X is any character not related to certification. <br />Liquid level probes, intrinsically safe for use in Class i, Div. 1, Group D and Class I Zone 0 Group IIA; hazardous locations when installed in <br />accordance with installation manual 577013-812, Form Nos. 85708 followed by 0 or 1, followed by -XXX, where X is any character not related to <br />certification. <br />Vacuum Sensor, intrinsically safe for use in Class I, Div. 1, Group D and Class I Zone 0 Group IIA; hazardous locations when installed in <br />accordance with installation manual 577013-836, Form No. 332175 -XXX. <br />ISD Pressure Sensor, Part No. 86119X -XXX where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and Class <br />I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 577014-019. May be provided with installation Kits Nos. <br />330020-515, -715 and/or -716 as described in the manual. <br />Steel tank sensors, Form Nos. 7943XX-4X0; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and <br />Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-616. <br />Single point hydrostatic sensors, Form Nos. 79438X-304; where X may be any character, intrinsically safe device for use in Class I, Div. 1, <br />Group D and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 577013-838. <br />Hydrostatic sensors, Form Nos. 7943XX-30X; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and <br />Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-795. <br />Sump sensors, Form Nos. 7943XX-20X; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and Class I <br />Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-301. <br />Vapor sensors, Form Nos. 7943XX-70X; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and Class I <br />Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-607. <br />Ground water sensors, Form Nos. 7943XX-62X; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and <br />Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-763. <br />Position sensitive sensor, Form No. 7943XX-323; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D <br />and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 577013-809. <br />Form No. 7943XX-333; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and Class I Zone 0 Group IIA; <br />Hazardous Locations when installed in accordance with manual 576013-616. <br />Oil/Water separator sensors, Form Nos. 7946XX-XXX; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group <br />D and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 577013-737. <br />Dispenser pan sensors, Form Nos. 7943XX 32X; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and <br />Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-306. <br />Containment sump sensors, Form Nos. 794380-35X; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D <br />and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-306. <br />Discriminating interstitial sensors, Form Nos. 79438X-343, where X may be any character, intrinsically safe device for use in Class I, Group D <br />and Class I, Zone 0, Group IIA Hazardous Locations when installed in accordance with manual 576013-826. <br />MicroSensors, Form Nos. 79438X-344; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and Class I <br />Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-285. <br />Discriminating interstitial sensors, alternate fluid cable, Form Nos. 79438X-345; where X may be any character, intrinsically safe device for <br />use in Class I, Div. 1, Group D and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-826. <br />2 to i Sensor Input Box, Form No. 857390-102 only for use with Sump, Position Sensitive and Hydrostatic Sensors, Form Nos. 794380 <br />followed by -208, -209, -301, -304, -323, intrinsically safe device for use in Class I, Div. 1, Group D and Class I Zone 0 Group IIA; Hazardous <br />Locations when installed in accordance with manual 577013-869. <br />Interstitial sensors, Form Nos. 7943XX-40X; where X may be any character, intrinsically safe device for use in Class I, Div. 1, Group D and <br />Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-617. <br />Mag Flex Probe, Model 8895 intrinsically safe for use in Class I, Group D; Class I Zone 0 AEx is IIA T4; hazardous locations when installed in <br />accordance with installation manual 577014-037. <br />http://database.ul.comlcgi-binIXYVItemplate/LISEXT/1 FRAMElshowpage.html?name=E... 7/17/2017 <br />