My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3434
>
2300 - Underground Storage Tank Program
>
PR0232398
>
COMPLIANCE INFO_2004-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:56:57 AM
Creation date
6/3/2020 9:57:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2015
RECORD_ID
PR0232398
PE
2361
FACILITY_ID
FA0003681
FACILITY_NAME
STOCKTON AUTO CENTER CAR WASH
STREET_NUMBER
3434
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12802011
CURRENT_STATUS
01
SITE_LOCATION
3434 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232398_3434 E HAMMER_2004-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br />4. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sums ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />❑ Vacuum <br />X Hydrostatic <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />Fill Sump # 1-87 <br />Fill Sump # 2-91 <br />Fell Sump#3-Diesel Fill Sump # <br />Sump Diameter: <br />42" <br />42" <br />42" <br />Sump Depth: <br />48''/2" <br />51 %" <br />52" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />11" <br />34" <br />29" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />16" <br />13" <br />18" <br />Condition of sump prior to <br />testing: <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested <br />Water Level 18" <br />Water Level 36" <br />Water Level 31" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />water and starting test: <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />9:10 <br />10:00 <br />10:50 <br />Initial Reading (Ri): <br />.001 <br />.001 <br />.001 <br />Test End Time. <br />9:40 <br />10:30 <br />11:20 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF-RI): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass ❑ Fail ❑ Pass ❑Fail <br />Is there a sensor in the sump? <br />X Yes ❑ No <br />X Yes ❑ No <br />X Yes C7 No ❑ Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />X Yes ❑ No [INA <br />X Yes []No [INA <br />X Yes ❑ No ❑ NA ❑ Yes F_� No ❑ NA <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No Cl NA <br />X Yes ❑ No ❑ NA ❑ Yes Cl No ❑ NA <br />Was sensor properly replaced and X Yes El No 11 NA X Yes 11 No Ll NA X Yes ❑ No 11 NA Ll Yes ❑ No LlNA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.