Laserfiche WebLink
SWRCB, January 2002 Page of <br />3. UNDER -DISPENSER CONTAINMENT (UDQ TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br />UDC # 1&2 UDC # 3&4 UDC # 5&6 <br />UDC # <br />UDC Manufacturer: <br />Western Fiberglass Western Fiberglass Western Fiberglass <br />UDC Material: <br />Fiberglass Fiberglass Fiberglass <br />UDC Depth: <br />31" 31" 31" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />11" 11" 11" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />5" 6" 16" <br />Condition of UDC prior to <br />testing: <br />Small amount of Small amount of Small amount of <br />Diesel Diesel Diesel <br />Portion of UDC Tested <br />Water Level 13" Water Level 17" Water Level 22" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />X Yes ❑ No ❑ NA X Yes []No ❑ NA X Yes ❑ No F. NA <br />Turbine shutdown response time <br />Not Alarmed Not Alarmed Not Alarmed <br />Is system programmed for fail- <br />safe shutdown?* <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />operational?* <br />❑ yes X No INA ❑ Yes X No ❑ NA ❑ Yes X No [a NA <br />Wait time between applying <br />water and starting test <br />5 Minutes 5 Minutes 5 Minutes <br />Test Start Time: <br />11:40 11:45 12:25 <br />Initial Reading (Ri): <br />.001 .001 .001 <br />Test End Time: <br />12:10 12:15 12:55 <br />Final Reading (RF): <br />.001 .001 .001 <br />Test Duration. <br />30 Minutes 30 Minutes 30 Minutes <br />Change in Reading (RF-Ri): <br />0 0 0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes .005/30 Minutes .005/30 Minutes <br />Test Result: <br />X Pass ❑ Fail X Pass ❑ Fail X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and X Yes ❑ No [INA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Wiped out small amount of Diesel from all UDC's Prior to Testing. <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to aM of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />