My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3434
>
2300 - Underground Storage Tank Program
>
PR0232398
>
COMPLIANCE INFO_2004-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:56:57 AM
Creation date
6/3/2020 9:57:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2015
RECORD_ID
PR0232398
PE
2361
FACILITY_ID
FA0003681
FACILITY_NAME
STOCKTON AUTO CENTER CAR WASH
STREET_NUMBER
3434
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12802011
CURRENT_STATUS
01
SITE_LOCATION
3434 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232398_3434 E HAMMER_2004-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br />3. UNDER -DISPENSER CONTAINMENT (UDQ TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br />UDC # 1&2 UDC # 3&4 UDC # 5&6 <br />UDC # <br />UDC Manufacturer: <br />Western Fiberglass Western Fiberglass Western Fiberglass <br />UDC Material: <br />Fiberglass Fiberglass Fiberglass <br />UDC Depth: <br />31" 31" 31" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />11" 11" 11" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />5" 6" 16" <br />Condition of UDC prior to <br />testing: <br />Small amount of Small amount of Small amount of <br />Diesel Diesel Diesel <br />Portion of UDC Tested <br />Water Level 13" Water Level 17" Water Level 22" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />X Yes ❑ No ❑ NA X Yes []No ❑ NA X Yes ❑ No F. NA <br />Turbine shutdown response time <br />Not Alarmed Not Alarmed Not Alarmed <br />Is system programmed for fail- <br />safe shutdown?* <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />operational?* <br />❑ yes X No INA ❑ Yes X No ❑ NA ❑ Yes X No [a NA <br />Wait time between applying <br />water and starting test <br />5 Minutes 5 Minutes 5 Minutes <br />Test Start Time: <br />11:40 11:45 12:25 <br />Initial Reading (Ri): <br />.001 .001 .001 <br />Test End Time: <br />12:10 12:15 12:55 <br />Final Reading (RF): <br />.001 .001 .001 <br />Test Duration. <br />30 Minutes 30 Minutes 30 Minutes <br />Change in Reading (RF-Ri): <br />0 0 0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes .005/30 Minutes .005/30 Minutes <br />Test Result: <br />X Pass ❑ Fail X Pass ❑ Fail X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and X Yes ❑ No [INA X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Wiped out small amount of Diesel from all UDC's Prior to Testing. <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to aM of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.