P <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue,Stockton, California 95205.6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:w►iwv.s1 oc� v.or /g ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Fe"o Kaiser Permanente Facility 7373 West Lane, Stockton Inspection Jan 11, 2013 <br /> Name: Address: Date: <br /> VIOLATIONS <br /> # C1 C2 M I Code Section HSC-CA Health and Saf Code;CFR=Code of Federal Regulabons <br /> C9=Class 1 violation:C2=Class 2 violation;M=Minor violation <br /> Nun-Pressurized piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (Mi) <br /> 703 CCR 2643(d} Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violatlon(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> GLASS I,CLASS 11or MINOR-Notice to Comply) <br /> Routine and Monitoring System Certification Underground Storage Tank inspection <br /> 115. Part of the site piping was closed in place on December 5, 7 and 10, 2012 under permit <br /> SR0065795 and secondary containment tightness testing on the remaining piping and the sump was not <br /> scheduled and witnessed by an EHD inspector. The testing is a condition of the closure permit and was <br /> required within one week of returning the system to operating condition. Failed to demonstrate that the <br /> Diesel UST system is structurally sound (permit conditions were not followed). Immediately schedule <br /> this test and provide 48 hours notification to the EHD. <br /> 302 & 308. Piping test bout was not pulled back in piping sump. Any potential release from the primary <br /> containment into the secondary containment in the Diesel piping does not flow into a collection sump. <br /> ,All secondary containment systems shall be sloped so that all releases will flow to a collection sump <br /> located at the low point of the underground piping. The testing technician pulled the test boot back, <br /> correcting the violations. <br /> Notes <br /> 1. Complete the following by February 11, 2013 and send to the San Joaquin County Environmental <br /> Health Department: <br /> a. The Return to Compliance Certification form. <br /> b. A statement explaining how each violation was corrected. <br /> c. Supporting documentation. <br /> 2. Discussed California Environmental Reporting System (CERS) with the operator. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TiME AT END'S CURRENT HOURLY RATE. <br /> Inspector: ,w Received By: �-- Title: <br /> EHD 2 04199!r2 Page 3 UST INSPECTION REPORT <br />