COMPLIANCE INFO_2009-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7373
>
2300 - Underground Storage Tank Program
>
PR0232494
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 12:52:58 PM
Creation date
6/3/2020 9:57:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232494
PE
2361
FACILITY_ID
FA0002602
FACILITY_NAME
KAISER PERMANENTE
STREET_NUMBER
7373
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09416023
CURRENT_STATUS
01
SITE_LOCATION
7373 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232494_7373 WEST_2009-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
429
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pagel of 2 <br /> Garrett Backus [EH] <br /> From: Garrett Backus[EH] <br /> Sent: Friday, February 24, 2012 8:26 AM <br /> To: 'Mike Lescure' <br /> Subject: RE: Kaiser Stockton fuel Oil System Corrections and Compliance <br /> Mike, <br /> See the list below that my department sent to Kaiser. The repairs will require an underground <br /> storage tank retrofit permit from my department. The permit application can be found here: <br /> http://www.sigov.org/ehd/Programs/Unitill/Retrofit.pdf <br /> 1. Title 22 California Code of Regulations UST emergency generator system exemptions are not <br /> allowed for USTs that are connected to both a generator and boiler piping. USTs which are only <br /> connected to an emergency generator get the emergency generator system exemptions. <br /> 2. The following is required to connect a steam boiler to the existing UST: <br /> a. The below—grade pipe between the day tank and generator engine needs secondary <br /> containment and monitoring. Usually this requirement is satisfied with double-walled pipe <br /> which drains to a sump with an electronic liquid sensor connected to the UST monitoring <br /> panel. The secondary containment needs to be tested triennially. Another option is to <br /> reroute the pipe above grade. <br /> b. The above-grade pipe needs a periodic line test which passes a leak threshold of 0.1 <br /> gallon/hour. Pressurized pipe needs an annual test. Gravity pipe needs a biennial test. <br /> Suction pipe needs a triennial test. This test is done by a SWRCB Licensed Tank Tester <br /> who is also a ICC certified technician. <br /> c. All above-grade pipe needs daily visual monitoring for leaks by Kaiser staff with the <br /> monitoring documented in a log. <br /> d. Installing the boiler and requirements listed in"a." must be done under an UST retrofit <br /> permit from the Environmental Health Department. The retrofit contractor must be ICC <br /> certified as a service technician. To break concrete, ICC certification as an UST <br /> installer/retrofitter is required. <br /> Garrett Backus <br /> Senior Registered Environmental Health Specialist <br /> San Joaquin County Environmental Health Department <br /> 600 E Main Street,Stockton CA 95202-3029 <br /> telephone: (209)468-2986 <br /> fax: (209)468-3433 <br /> email: gbackus@sjcehd.com <br /> ft://www.sjgov.org/�ehd/ProgMms/Others/unified.htin <br /> From: Mike Lescure [mailto:mlescure@lescurecompany.com] <br /> Sent: Thursday, February 23, 2012 2:08 PM <br /> To: Garrett Backus [EH] <br /> Cc: Brian Lescure <br /> Subject: Kaiser Stockton fuel Oil System Corrections and Compliance <br /> 3/16/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.