My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
633
>
2300 - Underground Storage Tank Program
>
PR0232519
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:00:21 PM
Creation date
6/3/2020 9:57:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0232519
PE
2361
FACILITY_ID
FA0000483
FACILITY_NAME
BILLS 76
STREET_NUMBER
633
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04321055
CURRENT_STATUS
01
SITE_LOCATION
633 E VICTOR RD STE A
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232519_633 E VICTOR_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
384
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> FacilitName: Bill's 76 Address: 633 E. Victor Rd. Lodi, CA 95240 Daiteection Jul 24, 2013 <br /> VIOLATIONS <br /> # C1 C2 M Code SeCtiOn HSC=CA Health and SafetyCode;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 104. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. The copy on file is dated July 23, 2012 <br /> and April 25, 2012. Received an updated copy dated July 2013, during the inspection. Take all <br /> necessary precautions to complete and submit a current copy of the financial responsibility annually. <br /> 201. The L6 87 annular sensor alarmed on July 13 and 15, 2013. The L1 91 turbine sump sensor <br /> alarmed on December 20, 2012 and on March 30, 2013. The designated operator did not document <br /> these alarms on the monthly designated operator report. The facility did not document the July 13, 2013, <br /> L6 87 annular sensor alarm, the March 30, 2013, L1 91 turbine sump sensor alarm, nor the December <br /> 20, 2012, L1 91 turbine sump alarm. Alarm maintenance records for these alarms were not on site. <br /> These records shall be kept on site for at least 3 years. Immediately locate and maintain the facility <br /> alarm log and alarm maintenance records on site and submit copies to the EHD by August 25, 2013. <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> July, April, and January 2013 designated operator monthly inspection reports and failed to check that <br /> they were responded to appropriately. The missing alarm includes, the L6 87 annular sensor that <br /> alarmed on July 13 and 15, 2013, the L1 91 turbine sump sensor that alarmed on December 20, 2012, <br /> and on March 30, 2013. The January 2013 designated operator report lacked the L1 91 turbine sump <br /> sensor alarm history print out. During the monthly inspection, the designated operator shall review the <br /> alarm history for the previous month, check that each alarm was documented and responded to <br /> appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> Inspector: Received By: Title: <br /> EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.