My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 7 of 9 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Fill Sump#87 Fill Sump#89 Fill Sump#91 Fill Sump# <br /> Sump Diameter: 48" 48" 48" <br /> Sump Depth: 72" 72" 73" <br /> Height from Tank Top to Top of 12" 13" 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 35" 34" 35" <br /> Electrical Penetration: <br /> Condition of sump prior to Fair Fair Fair <br /> testing: <br /> Portion of Sump Tested Above highest Above highest Above highest Above highest <br /> penetration penetration penetration penetration <br /> Sump Material&Manufacturer: Fiberglass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 11:00am 11:00am 11:00am <br /> Initial Reading(Rj): 0.6888 0.6377 3.2060 <br /> Test End Time: 11:15am 11:15am 11:15am <br /> Final Reading(RF): 0.6889 0.6376 3.2063 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-RI): 0.00011 0.00009 0.00032 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> MOMMEJUMM <br /> Is there a sensor in the sump? ®Yes ❑No Yes ❑No ®Yes ❑No ®Yes No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No ®NA []Yes❑No ®NA ❑Yes❑No ®NA ❑Yes❑No ®NA <br /> detected? <br /> Was sensor removed for testing? ®Yes No ❑ ®Yes El No ❑ <br /> ®Yes ❑No ❑NA ®Yes El No❑NA NA NA <br /> Was sensor properly replaced and ®I, s ❑No [-]NA ®Yes [:]No❑NA ®Yes ❑No❑NA ®Yes ❑No❑NA <br /> verified functional after test <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.