Laserfiche WebLink
y , <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br /> MONITORING SYST CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON#201383(N-2515-1-1) Bldg.No.: <br /> Site Address: 1960 W.11TH STREET@ CORRAL HOLLOW City: TRACY Zip: 95376 <br /> Facility Contact Person: MGR-HELEN Contact Phone No.: 836-3181 <br /> Make/Model of Monitoring System: Veeder Root TLS350 Date of Testing/Servicing: 2/15/2013 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ed serviced: <br /> Tank ID: Tl-SUPREME Tank ID: T2-PLUS <br /> In-Tank Gauging Probe. Model: mag W In-Tank Gauging Probe. Model: maq <br /> Annular Space or Vault Sensor. Model: 409 W�Annular Space or Vault Sensor. Model: 409 <br /> Piping Sump/Trench Sensor(s). Model: 208 V',Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: 208 V Fill Sump Sensor(s). Model: 208 <br /> (� Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD v/0:Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> r Tank Overfill/High-Level Sensor.Model: flapper Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment and model in Section E on Pa e 2. Others equipment a and model in Section E on Page 2). <br /> Tank ID: T3-REGULAR Tank ID: <br /> (ir In-Tank Gauging Probe. Model: magin-Tank Gauging Probe. Model: <br /> ry Annular Space or Vault Sensor. Model: 409 Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: 208 17 Piping Sump/Trench Sensor(s). Model: <br /> (y' Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: <br /> (v Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> F Electronic Line Leak Detector. Model: Veeder Root PLLD Electronic Line Leak Detector. Model; <br /> Tank Overfill/High-Level Sensor.Model: flapper r''Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pa e_2) _. Other(specify equipment a and model in Section E on Pa e 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID; <br /> Dispenser Containment Sensor(s).Model: 208 r'c Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). rll_'','Shear Valve(s). <br /> r Dispenser containment Float(s)and Chain(s). r';'Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/. <br /> ID: ID' <br /> Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s),Model: 208 <br /> Shear Valve(s). ryShear Valve(s). <br /> �~ Dispenser Containment Floats and Chain(s). ',Dispenser Containment Float(s)and Chain(s). <br /> Dispenser S/10 Dispenser 11/12 <br /> ID: 10.. <br /> Dispenser Containment Sensor(s).Model: 208 fV—`,`Dispenser Containment Sensor(s),Model: 208 <br /> FV Shear Valve(s). W Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). rDispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information:,for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report;(check aU that apply):P System set- <br /> up FV Alarm history report <br /> Technician Namerint: Steven Wiliems <br /> (p } Signature: <br /> Certification No.: 836743 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)80011633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/15/2013 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />