My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2015-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2016
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1960\PR0232534\RETROFIT 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ❑✓ Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ✓❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Set;attached testing procedures Equipment Resolution: Inches <br /> SuSump# 91 Sump# Diesel Sump# <br /> SumT!rFibe7rglass 48" 48" 48" <br /> Sum71" 75" 76" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 12" 12" 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to i owest 28" 30" 32" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Fair Fair Fair Fair <br /> Portion of Sump Tested' Above highest penetration Above highest penetration Above highest penetration Above highest penetration <br /> Does turbine shut down when <br /> sump sensor detectsliquid(both ❑ []No ❑✓ <br /> Yes No NA Oyes ❑No NA [--]yes[] ✓❑ El NA Yes ao ✓❑N IA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A I N/A N/A <br /> Is system programmed for fail-safe <br /> ❑ <br /> shutdown?* []NO ❑✓Yes No NA ❑Yes ❑No ❑✓ NA ❑Yes❑ No Z NA El Yes ❑No ❑✓NA <br /> Was fail-safe verified to be <br /> operational?* <br /> [:]Yes [:]No ✓❑NA ❑Yes [:]No ✓❑NA [:]Yes []No ✓❑NA ❑Yes [—]No [Z]NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 minutes 15 minutes 15 minutes 15 minutes <br /> test: <br /> Test Start Time: 11:45am 1:02pm 11:45am <br /> Initial Reading(RI): 1.88370 Inches 0.69354 Inches 4.29838 Inches Inches <br /> Test End Time: 12:OOpm 1:17pm 12:OOpm <br /> Final Reading(RF): 1.88422 Inches 0.69349 Inches 4.29907 Inches Inches <br /> Test Duration: 15 mins 15 mins 15 mins 15 mins <br /> Change in Reading(RF-Rj): 0.00052 0.00005 0.00069 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: ❑✓ Pass ❑Fail ❑✓ Pass ❑Fail ✓❑Pass ❑Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? ✓❑Yes ❑No [INA [Z]Yes ❑No [INA ✓❑Yes []No []NA ❑✓ Yes [-]No []NA <br /> Was sensor properly replaced and ✓ Yes No NA ✓ Yes No NA ✓ Yes <br /> verified functional after testin ? ❑ ❑ ❑ ❑ ❑ ❑ ❑ []No ❑NA ✓❑Yes E]No E]NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page