My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2015-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2016
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1960\PR0232534\RETROFIT 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer m Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum p Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br /> Fill Sump# 87 Fill Sump#91 Fill Sump# Diesel Fill Sump# <br /> -Sump,Diameter: 48" 48" 48" <br /> -Sump Depth: 72" 73" 73" <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: 1a" 14" 14" <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: 33" 35" 3s" <br /> Condition of sump prior to Fair Fair Fair Fair <br /> testing: <br /> Portion Of Sump Tested I Above highest penetration Above highest penetration Above highest penetration Above highest penetration <br /> -Sump Material: <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes 15 minutes <br /> -starting test: <br /> Test Start Time: 10:09am 9:49am 9:54am <br /> -Initial Reading(RI): 4.6907 Inches 3.52966 Inches 4.98819 Inches Inches <br /> Test End Time: 10:24am 10:04am 10:09am <br /> Final Reading(RF): 4.6907 Inches 3.52996 Inches 4.98849 Inches Inches <br /> Test Duration: 15 minutes 15 minutes 15 minutes 15 minutes <br /> Chan a in Readin (RF-RI): 0.0000 0.00030 0.00030 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: p Pass ❑Fail p Pass ❑Fail p Pass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? ®Yes ❑No m Yes ❑No Z Yes ❑No Z Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is 21 Yes ❑No ❑NA ®Yes ❑No ❑NA p Yes ❑No ❑NA p Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes ❑No ❑NA ®Yes ❑No ❑NA ®Yes ❑No ❑NA <br /> Was sensor properly replaced and ©Yes ❑No ❑NA p Yes ❑No ❑NA p Yes ❑No ❑NA p Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.