My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:22:11 PM
Creation date
6/3/2020 9:58:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0232555
PE
2361
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
01
SITE_LOCATION
2224 MANTHEY RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232555_2224 MANTHEY_1998-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AlItech ENO <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 209-532-7320; Fax: 209-533-2650 r ;,a <br /> California Contractor 623541 A-Haz <br /> Mike@MtechPetro.com Ef'dVI�Qfia�,9f�Nfi HEALTH <br /> I'E( ^ !7/;ERV10ES <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: California Stop Date of Testing/Servicing: February 25,2005 <br /> Facility Address: 2224 Manthey Road,Stockton CA 95205 <br /> Facility Contact Person:Nancy Le Contact Phone No.:462-7621 <br /> Regulatory agency: San Joaquin Health;Inspector: Steven Shih;Phone:468-9850;Fax 468-3433 <br /> Make/Model of Monitoring System:Veeder-Root TLS-350 <br /> b*:0FUA In Compliance)or a❑Preumbsry Report(Uwv n kw laws Exist) <br /> B. Invento of Equipment Tested/Certified: <br /> Tank M.Regular Tank Tank ID:Premium Tank <br /> N In-Tank Gauging Probe. Model:Mag 1 ®In-Tank Gauging Probe. Model:Mag 1 <br /> N Annular Space or Vault Sensor. Model:Wrap-Around N Annular Space or Vault Sensor. Model:Wrap-Around <br /> N Piping Sump Sensor(s). Model:Non-Discriminating N Piping Sump Sensor(s), Model:Non-Discriminating <br /> ❑Fill Sump Sensor(s). Model:NONE ❑Fill Sump Sensor(s). Model:NONE <br /> N Mechanical Line Leak Detector. Model:Vaporless LD-2000 N Mechanical Line Leak Detector. Model:Vaporless LD-2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> N Tank Overfill/High-Level Sensor. Model:Drop Tube N Tank Overfill/High-Level Sensor. Model:Drop Tube <br /> N Fillill buckets tested NPass ❑Fail N Fills ill buckets tested ®Pass ❑Fail <br /> Tank ID:Diesel Tank Tank ID: <br /> N In-Tank Gauging Probe. Model:Mag 1 ❑In-Tank Gauging Probe. Model: <br /> N Annular Space or Vault Sensor. Model:Wrap-Around ❑Annular Space or Vault Sensor. Model: <br /> N Piping Sump Sensor(s). Model:Non-Discriminating ❑Piping Sump Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model:NONE ❑Fill Sump Sensor(s). Model: <br /> N Mechanical Line Leak Detector. Model:Vaporless LD-2000 ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model:Drop Tube ❑Tank Overfill/High-Level Sensor. Model: <br /> ® <br /> FiEMill buckets tested NPass ❑Fail ❑Fills ill buckets tested ❑Pass ❑Fail <br /> Dispenser ID: 1&2 N Sump:❑Dry NWater❑Product Dispenser ID:3&4 N Sump:NDry❑Water❑Product <br /> N Dispenser Containment Sensor(s). Model:Non-Discriminating N Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> N Shear Valve(s) (Functional test) N Shear Valve(s) (Functional test) <br /> ❑Dispenser Containment Floa s and Chain s). ❑Dispenser Containment Floats and Chains . <br /> Dispenser ID:5&6 N Sump:®Dry❑Water❑Product Dispenser ID: 7&8 N Sump:NDry❑Water❑Product <br /> N Dispenser Containment Sensor(s). Model:Non-Discriminating ®Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ❑Di ser Containment F122s and Chains). ❑Di ser Containment Floa s and Chains . <br /> Dispenser ID: ❑Sump:❑Dry❑Water❑Product Dispenser ID: ❑Sump:❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑DiTqjser Containment Floa s and Chains . ❑Dis r Containment Floats and Chains . <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers'guidelines. Attached to this Certification is information(e.g. manufacturers' checklists)necessary to verify that this <br /> Information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): N System set-up N Alarm history report <br /> Technician: 7y 4e A Mike Dotten,California Contractor License.No.:623541 <br /> Certification:Veeder-Root:341-32-6743;Level 4. <br /> Page 1 of 3 03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.