Laserfiche WebLink
D. Results.of Testing/Servicing <br /> Software Version Installed: 122.0 <br /> Complete---_the following checklist: <br /> •Yes EEII No* Is the audible alarm MMtional? Outside Audible Alarm? <br /> •Yes El No* Is the visual alarm operational? <br /> •Yes El No* Is theLnnt function operatRonal? Not installed. <br /> •Yes El No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> •Yes El No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their REper operation? <br /> [I Yes n No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> 0 N/A operational? <br /> 0 Yes [I No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> El N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) 0 Sump Sensors; 0 Dispenser Containment Sensors. <br /> Did you confirin22!iti�ve shut-down due to leaks and sensor failureldisconnection? 19 Yes; Ej No. <br /> 0 Yes E] No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill R2int s)and opeEatin pEpEIL? If so <br /> at what Ecent of tank R2pp does the alarm trigger? <br /> �y <br /> 0 Yes* El No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br /> LeplaocW and list the manufacturer name and model for all EM!Lmmentts in Section E,below. <br /> pK_ <br /> ED Yes* Ej No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> JZ Product; N Water. If yes,describe causes in Section E,below. <br /> Yes ❑ No* Was M2nitorin system set-up reviewed to ensure proper settiM?Attach set _Vorts,if applicable <br /> r <br /> Yes El No* Is all monitorin <br /> uipmento gEELtLional gEr manufacturer's ? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Regular LLD was replaced and passed the retest. Product/water was found in the Diesel piping sump <br /> and the #1-2 dispenser pan, Both were cleaned out with a shop vac and the residue left on site in the Hazardous Waste <br /> barrels provided. We dumped the water from the fillspill test in the waste barrel as well. <br /> Page 2 of 3 03/01 <br />