My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:22:11 PM
Creation date
6/3/2020 9:58:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0232555
PE
2361
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
01
SITE_LOCATION
2224 MANTHEY RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232555_2224 MANTHEY_1998-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,january 2002 Page of <br /> j 6. PIPING SUMP TESTING <br /> Test Method Developed By: 0 Sump Manufacturer YIndustry Standard 0 Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 0 Pressure ❑Vacuum ydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Sump# Sum <br /> b <br /> Sump# Sump# p#11 <br /> Sump Diameter: r e, �s <br /> Sump Depth: <br /> Sump Material: -ZsIj, . <br /> Height from Tank Top to Top of ,, <br /> Highest Piping Penetration: <br /> Height from Tank-Top to Lowest ;, <br /> Electrical Penetration: l <br /> Condition of sump prior to testing: <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both 0 Yes ❑No 0 NA ❑Yes 0 No ❑NA aV6 ❑NoDN,A ❑Yes ❑No ❑NA <br /> product and Avater)?' <br /> Turbine$hutdown response time <br /> Is system prograinnied for fail-safe 0 yes 0 No ❑Yes 0 No 0 NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> shutdowif?* <br /> Was fail-safe verifted to be 0 s 0 No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> o eratiotutl?' <br /> Wait time between applying <br /> pressure/acuumAvater and starting <br /> test: 5 `y+ <br /> Test Start Time: ` <br /> Initial Reading(RI): <br /> Test End Time: 7Do , DO a, <br /> Final Reading(RF): Da 0 <br /> Test Duration: E- <br /> Change in Reading(RF-Rz): tomw <br /> Pass/Fail Threshold or Criteria: <br /> R <br /> Test Result: " Pass 0 Fail Pass ❑Fail ass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? Yes ❑No ❑NA �,Wes ❑No ❑NA ftes ❑No ❑NA 0 Yes 0 No ❑NA <br /> Was sensor properly replaced and Vy <br /> es ❑No ❑NA *es ❑No ❑NA . '_Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to 4gy of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />