My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:28:16 AM
Creation date
6/3/2020 9:58:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,.January 2002Page 6. <br /> 7. UNDER- ISPENSER CONTAINMENT (UD CIRESTING <br /> Test Method Developed By: FIUDC Manufacturer F-1 Industry Standard X� Professional Engineer <br /> Other (Specify) <br /> Test Method Used: F] Pressure Vacuum Hydrostatic <br /> 0 Other (Spec) <br /> Test Equipment Used: vp 1 t Equipment Resolution: +-.0 0 2" <br /> UDC# 9/10 UDC# 11/12 UDC# 7/8 UDC# <br /> UDC Manufacturer: unknown unknown unknown <br /> UDC Material: fiberglass fiberglass fiberglass <br /> UDC Depth: 36" 36" 36" <br /> Height from UDC Top to Top of <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 911 911 911 <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good good <br /> Portion of UDC Tested: 1 1311 1311 1311 <br /> Does turbine shut down when <br /> sump sensor detects liquid(bothX❑yes❑N�N Yes�N�N Yes❑No[:]NAF]Yes❑No�T <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec 2-5 s e c <br /> Is system programmed for fail-safe _ <br /> [:] <br /> ❑ ❑ ❑ ❑ � ❑ ❑ �—� T <br /> shutdown?* X Yes N N X Yes N N X Yes N N X Yes No <br /> Was fail-safe verified to be ❑ � ❑ ❑ � [:]Yes❑ <br /> operational?* X❑Yes N N [flYes N N X❑Yes N N No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min 5min <br /> test: <br /> Test Start Time: 1 11:18 11:22 11:30 <br /> Initial Reading(Rl): 0 0 0 <br /> Test End Time: 11:33 11:37 11:45 <br /> Final Reading(RF): -.00081, -.000511 -.000211 <br /> Test Duration: 15min 15min 15min <br /> Change in Reading(R F-Rl ): -.000811 - .0005" -.000211 <br /> Pass/Fail Threshold or Criteria: +-.00211 +-.00211 +-.002" <br /> Was sensor removed for testing? X Yes❑N NA MYes N NA EXYes No❑NA Yes <br /> NN <br /> Was sensor properly replaced and F_71 � <br /> verified functional after testing? ❑Ye�N NAYe�NNAXYe�N�NA Yes❑N ❑ <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> di.sp 7/8 failed at 13" and passed at 6" <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to a�of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />