My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:28:16 AM
Creation date
6/3/2020 9:58:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,.January 2002 Page 5. <br /> 7. UNDER- ISPENSER CONTAINMENT (UDArESTING <br /> Test Method Developed By: F] UDC Manufacturer F-1 Industry Standard ❑X Professional Engineer <br /> ❑ Other (Spec) <br /> Test Method Used: ❑ Pressure Vacuum Hydrostatic <br /> ❑ Other (Specify) <br /> Test Equipment Used: vp 1 t Equipment Resolution: +-.0 0 2" <br /> UDC# 1/2 UDC# 3/4 UDC# 5/6 UDC# 7/8 <br /> UDC Manufacturer: unknown unknown unknown unknown <br /> UDC Material: fiberglass fiberglass fiberglass fiberglass <br /> UDC Depth: 36" 36" 36" 36" <br /> Height from UDC Top to Top of 1111 1111 11" 1111 <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 911 911 911 91, <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good good good <br /> Portion of UDC Tested: 1 1311 1311 1311 1311 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X❑yes❑No❑N Yes ]No�N Yes❑N�N E Yes❑No❑N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec 2-5sec 2-5 s e c <br /> Is system programmed for fail-safe ❑ ❑ ❑ � ❑ <br /> shutdown?* X❑Yes N N X❑Yes N N X❑Yes N N X Yes No <br /> Was fail-safe verified to be ❑ ❑ E] ❑ ❑ � ❑ ❑ � ❑ ❑ n„T <br /> operational?* R Yes N N X Yes N N X Yes N N X Yes No J`� <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min 5min 5min <br /> test: <br /> Test Start Time: 9:33 10:2 2 11:19 11:24 <br /> Initial Reading(Ri): 0 0 0 0 <br /> Test End Time: 9:48 10:38 11:34 11:34 <br /> Final Reading(RF): - .000611 - .0004" -.00081, -.2606" <br /> Test Duration: 15min 15min 15min 15min <br /> Change in Reading(RF-Rl ): -.000611 -.0004" -.000811 - .2606" <br /> Pass/Fail Threshold or Criteria: +-.002" +-.002" +-.002" +-.002" <br /> son= <br /> Was sensor removed for testing? X JN4 Yes No� � <br /> Was sensor properly replaced and EI,esE]Nc❑NA [flYeC1Nc❑NAMYe f]NcF]NA MYes❑No[]N <br /> verified functional after testing? <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> disp 7/8 failed at 13" and passed at 6" <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />