My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_1995-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:45:30 PM
Creation date
6/3/2020 9:58:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2011
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_1995-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s4goy.o[g/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility Ramos Oil-French Cam Facility 10842 South Harlan Road Lathrop Inspection Oct 31 2011 <br /> Name: I� Address: � p Date: <br /> Facility <br /> Contact: Dave Nelson - , fv �.,` Title: DirectorSafety&Compliance M1371-3289 <br /> Inspection <br /> Type: XRoutine XMonitoring System Certification Installation Complaint—ID#: Other: <br /> (Authority HSC 25289) <br /> Consent for: Xlnspection XSampling XPhotos Granted by: Title: <br /> Monitoring INCON TS-1000 Piping XPressurized _'Suction i Gravity Overfill Mechanical Audible/visual <br /> Panel: System: Prevention: <br /> UST 1 <br /> ---Product--- -----DSL ---- ------------- ------------------------ -------------- -------------- -------------- ----------- -------------- <br /> Designated SDelgado Date:Sam Exp <br /> Operator: g Dat . 02/25/13 Violations: M1-Release Detection M2-Release Prevention M3—Both <br /> On Site Service ICC Exp„ Manufactu Gs <br /> Technician: ��., ' 9, }}� Date: l�" �� Training: 1 L)' :' � 7 1 rr F.y �7 (� <br /> VVI �--� v� <br /> L- <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> Cl=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EH41f LCI <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHDat leas 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not rformed on system located within 1000'of public well,or <br /> failures not repaired and retested 2, <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/z years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(1) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned ul after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector: Received By: Title: <br /> Thuy Tran (209) 468-8257 ` <br /> EHD 23-02 Rev 09/01/11 Page 1 W UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.