My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_1995-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:45:30 PM
Creation date
6/3/2020 9:58:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2011
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_1995-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sociov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Facility Inspection Oct 31, 2011 <br /> Name: Ramos Oil - French Camp Address: 10842 South Harlan Road, Lathrop I Date: <br /> VIOLATIONS <br /> HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> # C1 C2 M Code Section C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> -=7 <br /> 204 CCR 2715(c) Designated operator monthly inspection:(1)alarms not documented;(2-4)spill containers,UDCs,and sumps <br /> if necessary)not inspected;(5)required test dates not checked or noted;(6)employee training not verified <br /> 205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br /> 206 CCR 2715(Q Designated operator employee training:(1)not performed;(2)not current for at least one employee on site; <br /> (3)to not kept <br /> 207 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> 301 HSC 25292.1 LIST system is not operated to prevent unauthorized release,including spills and overfills <br /> 302 HSC 25291(b) LIST monitoring system incapable of detecting leak from primary containment into secondary containment(mi) <br /> 303 CCR 2630(d) LIST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (MI) <br /> 304 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled LIST (MI) <br /> 305 CCR 2636(0(1) Failed to maintain a continuous monitoring system for underground piping&LDCs that activates an (Mi) <br /> audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 306 CCR 2631(a) Primary containment is not product tight <br /> 307 HSC 25291(a)(2) Secondary containment for LIST system is not tight <br /> 308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> 309 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (11012) <br /> 310 HSC 25291(e) Water in 21 containment not removed,analyzed&properly disposed of <br /> 311 CCR 2636(0(2) Line leak detector(s)not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mi) <br /> 312 CCR 2635(b) No spill container or overfill prevention system installed (11012) <br /> 313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means to keep (M2) <br /> the spill container empty <br /> 314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (11112) <br /> 315 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br /> 316_ CCR 2631.1(a) LIST system is not compatible with the substance stored <br /> 317 HSC 25298(a) Illegally abandoned LIST system <br /> IN <br /> a <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 401 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and(d) <br /> for a UST system installed after July 1,2004,were not submitted <br /> 402 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 403 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 404 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 405 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of <br /> HSC 25290.2(d) liquid or vapor from the primary containment into the secondary containment <br /> 406 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the <br /> LIST system not maintained <br /> 407 HSC 25290.16) LIST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> HSC ME, W <br /> 25290.2(i) pr ssure test aperoved bX SWRCB;Q�test method deemed esuivalent to or W bx the SWRCB <br /> i 7 7 <br /> I - <br /> 501 CCR 2636(f)(6) Emergency generator monitoring system not checked daily or log not kept if no leak detector (Mi) <br /> 502 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept (Mi) <br /> 601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br /> 602 HSC 25283.5(a)(2) Structure that the LIST is located in does not provide for secondary containment <br /> 603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br /> 604 HSC 25283.5(a)(5) LIST installed after July 1,2003,does not meet or exceed applicable sections of HSC 25291 <br /> 7774-77-1 <br /> 701 CCR 2643(d) Daily monitoring of suction piping(pre-January 1,1984)not performed <br /> Inspector. Received By: <br /> Title: <br /> I <br /> Thuy Tran (209) 468-8257 I ('d <br /> EHD23-02 Rev 09/01/11 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.