Laserfiche WebLink
Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://Www.waterboards.ca.gov.) <br />MONITORING T CERTIFICATION <br />For Use By All Jurisdictions Within the State of Caldbmia <br />Authority Cited. Chapter 6.7, Health and Safety Code; Chapter 96, Division 3, Title 23, Califomia Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: _Ramos Oil Company Bldg. No.: <br />Site Address: _10842 S. Harlan Road city: _French Camp Zip: <br />Facility Contact Person: _Dave Nelson Contact Phone No.: 916-371-2570 <br />Make/Model of Monitoring System: —TLS -350 Date of Testing/Servicing: _10/30/13 <br />B. Inventory of Equipment Tested/Certified <br />Check the aDiorooriate boxes to Indicate specific equipment ins cted/serviced: <br />Tank ID: Diesel <br />Tank to: <br />x <br />_1 <br />In -Tank Gauging Probe. <br />Model: <br />Mag 1 <br />❑ <br />In -Tank Gauging Probe. <br />Model: <br />x <br />Annular Space or Vault Sensor. <br />Model: <br />_VR 303 <br />u <br />Annular Space or Vault Sensor. <br />Model: <br />x <br />Piping Sump / Trench Sensor(s). <br />Model: <br />VR 208 <br />El <br />Piping Sump 1 Trench Sensor(s). <br />Fill Sump Sensor(s). <br />Model: <br />Model: <br />x <br />Fill Sump Sensor(s). <br />Model: <br />VR 208 <br />❑ <br />F! <br />Mechanical Line Leak Detector. <br />Le. <br />Model: <br />x <br />Mechanical Line Leak Detector. <br />Model: <br />_VMI LD 2000 <br />❑ <br />Electronic Line Leak <br />Model: <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />❑ <br />SenDetector. <br />Tank Overfill / High-level Sensor. <br />High-Level <br />Model: <br />0 <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Other (specify equipment type and model in Section E on Page 2). <br />❑ <br />Other ui ment and model <br />seci <br />in Section <br />E on Page 2 . <br />Tank 10: <br />Tank ID: <br />❑ <br />In -Tank Gauging Probe. <br />Model: <br />❑ <br />In -Tank Gauging Probe. <br />Model: <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />D <br />Annular Space or Vault Sensor. <br />Model: <br />0 <br />Piping Sump / Trench Sensor(s). <br />Model: <br />0 <br />Piping Sump / Trench Sensor(s). <br />Model: <br />❑ <br />Fill Sump Sensor(s). <br />Model: <br />D <br />Fill Sump Sensor(s). <br />Model: <br />0 <br />Mechanical Line Leak Detector. <br />Model: <br />(] <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Electronic Line Leak Detector. <br />Model <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Other a ui ment a and model in Section E on Page 2). <br />❑ <br />s cin E on Pa e 2 . <br />Otherui ment a and model in Sectio <br />Dispenser ID: _1-2 <br />Dispenser ID: _3.4 <br />x <br />Dispenser Containment Sensor(s). <br />Model: <br />VR 208 <br />x <br />Dispenser Containment Sensor(s). <br />Model: _VR 208 <br />❑ <br />Shear Valve(s). <br />Li <br />Shear Valve(s). <br />0 <br />Disp2nser Containment Floats and Chain(s). <br />:i <br />Dis nser Containment Floats and Chain(s). <br />Dispenser ID: _Satellite 1 <br />Dispenser ID: _Satellite 4-5 <br />x <br />Dispenser Containment Sensor(s). <br />Model: <br />VR 208 <br />x <br />Dispenser Containment Sensor(s). <br />Model: VR 208 <br />❑ <br />Shear Valve(s). <br />0 <br />Shear Valve(s). <br />❑ <br />Dispenser ContalnMg2 Float s and Chains . <br />❑ <br />Dispenser Containment Floats and Chain(s). <br />Dispenser ID: _Satellite _2-3 <br />Dispenser ID: —5— <br />* <br />Dispenser Containment Sensor(s). <br />Model: <br />VR 208 <br />x <br />Dispenser Containment Sensor(s). <br />Model: _VR 208 <br />❑ <br />Shear Valve(s). <br />❑ <br />Shear Valve(s). <br />❑ Dise2neer Containment Floats and Chains <br />❑ <br />Dis nser Containment Floats and Chaln s . <br />`If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the faciky. <br />C. Certification - 1 certify that the equipment identified in this document was Inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification are information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Piot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ASystem set-up ^Ianm history report <br />Technician Name (print): John Puumala Signature: <br />Certification No.: A29358 Li ns o.: 811471 <br />Testing Company Name: JP Petroleum Service Phone No.:(_916---)_372-5693 <br />Testing Company Address: 3065 Asante Lane, W. Sacto Ca 95691 _ Date of Testing/Servicing: _10-30/13 <br />Monitoring System Certification Page 1 of 4 12/07 <br />2/21/07 <br />