Laserfiche WebLink
LINE LEAIMETECTOR (LLD) TE <br />TEST DATE: October 30, 2012 <br />A1. FACILITY <br />Name Ramos Oil #4376 <br />Address 10842 S. Harlan Road, French Camp, CA 95231 <br />Phone # 800-477-7266 x 244 <br />Contact Sam Delgado <br />REPORT <br />A2. OWNER <br />Name <br />Ramos Oil <br />Address <br />1515 South River Road, West Sacramento, CA 95691 <br />Phone # <br />916-371-2570 <br />Contact <br />Dave Nelson <br />A3. C U P A <br />1 <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Diesel <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />MLLD <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />October 16, 2012 <br />VMI 88LD-2000 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Thuy Tran <br />12021026 <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Phone # <br />916-373-1166 <br />I. LINE LEAK DETECTOR TEST RESULTS <br />Test Equipment Used: Vaporless VMI LDT-890 <br />_Tank number <br />1 <br />Product contained <br />Diesel <br />Leak Detector Type <br />MLLD <br />Leak detector make/model _ <br />VMI 88LD-2000 <br />Serial number <br />12021026 <br />Functional Element Holding_ (psi) <br />24 <br />Resiliency (ml) <br />_ <br />138 _ <br />Test leak rate (gph) <br />3.00 <br />Pump pressure (psi) <br />28 <br />-- <br />Metering pressure (psi) <br />14 <br />Pressure Restriction Reduction (psi) <br />14 <br />Length of Restriction Test (seconds) <br />30 <br />Full Flow Opening time (seconds) <br />6 <br />TEST RESULT <br />PASS <br />Tank number <br />Product contained <br />-- <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml)Test <br />leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />_Tank number <br />1 <br />Product contained <br />Diesel <br />Leak Detector Type <br />MLLD <br />Leak detector make/model _ <br />VMI 88LD-2000 <br />Serial number <br />12021026 <br />Functional Element Holding_ (psi) <br />24 <br />Resiliency (ml) <br />_ <br />138 _ <br />Test leak rate (gph) <br />3.00 <br />Pump pressure (psi) <br />28 <br />-- <br />Metering pressure (psi) <br />14 <br />Pressure Restriction Reduction (psi) <br />14 <br />Length of Restriction Test (seconds) <br />30 <br />Full Flow Opening time (seconds) <br />6 <br />TEST RESULT <br />PASS <br />Tank number <br />Product contained <br />-- <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml)Test <br />leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />J. COMMENTS: <br />Red Jacket MLLD failed. Installed VMI adjustable MLLD and retested with passing results. <br />Signature: WALTON ENGINEERING, INC. <br />Technician: Jessie Wadkins / 635391 5307886 -UT Date: October 30, 2012 <br />