Laserfiche WebLink
ANNUAL *ILL CONTAINER <br />TEST DATE: October 30, 2012 <br />Al. FACILITY <br />Name Ramos Oil #4376 <br />Address 10842 S. Harlan Road, French Camp, CA 95231 <br />Phone # 800-477-7266 x 244 <br />Contact Sam Delgado <br />PORT <br />A2. OWNER <br />Name Ramos Oil <br />Address 1515 South River Road, West Sacramento, CA 95691 <br />Phone # 916-371-2570 <br />Contact Dave Nelson <br />A3. C U P A <br />Tank Number <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Product contained _ <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />October 16, 2012 <br />Spill container capacity (US gallons) <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Thuy Tran <br />Spill container manufacturer <br />Contact <br />Dulcinea Coven <br />Phone # <br />209-468-8257 <br />Spill container depth (inches) <br />Phone # <br />916-373-1166 <br />K. SPILL CONTAINER TEST RESULTS <br />Measuring Equipment Used: Caldwell System 2001 / Walton Engineering (Level Change Indicator) <br />Tank Number <br />1 <br />Product contained _ <br />Diesel <br />Spill container capacity (US gallons) <br />5 <br />Spill container manufacturer <br />OPW <br />Spill container depth (inches) <br />15.00 <br />Is the spill container located in a sump? <br />Yes <br />Does sump have a liquid sensor installed? <br />Yes <br />Condition of spill container prior to testing <br />Dry <br />Portion of spill container tested <br />Entire <br />Depth of water level from bottom (inches) <br />13.50_ <br />Wait time for water level to stabilize (hr:min) <br />_ <br />0:05 <br />Test start time <br />_ <br />12:00 <br />Test end time <br />12:30 <br />Test duration (hr:min) <br />0:30 <br />Change in water level (t 0.000 inches) <br />_ <br />0.002 <br />Pass/Fail threshold (0.005 inches /% <br />L. COMMENTS: <br />Replaced OPW fill cap on the Diesel product. <br />Replaced the OPW drain valve on the Diesel bucket. <br />W�J) _ <br />wALTON <br />Signature: <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: October 30, 2012 <br />Hr.) <br />0.005 <br />TEST RESULT <br />PASS <br />L. COMMENTS: <br />Replaced OPW fill cap on the Diesel product. <br />Replaced the OPW drain valve on the Diesel bucket. <br />W�J) _ <br />wALTON <br />Signature: <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: October 30, 2012 <br />