My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 11:43:46 AM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, Califomia 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Ramos Oil -French Cam Facility 10842 South Harlan Road, Lathrop Inspection Oct 30, 2012 <br />Name: p Address: p Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR -Notice to Comply) <br />UST Inspection: Routine & Annual Monitoring System Certification <br />201. Maintenance & monitoring records not maintained for 3 years. Unable to locate the most recent <br />secondary containment test results performed on 12/16/2011 in the facility's binder on site. Binder <br />contained secondary containment test results for 2008 and 2005. These records shall be kept on site for <br />at least 3 years . Immediately locate the secondary containment test results and maintain the record on <br />site. Explained how this was completed. <br />301,303,304,305. UST system is not operational to prevent unauthorized releases, including spills and <br />overfills. UST monitoring system is not maintained to detect a leak at the earliest opportunity. Monitoring <br />system is not present in the interstitial space of the double wall UST. There is no continuous monitoring <br />system for the underground piping and under dispenser containment that activates audible and visual <br />alarm or stops the flow of product at dispenser when it detects a leak. <br />The Incon TS-1000EF1 motherboard is inoperable and unresponsive. The technician was on the phone <br />with an Incon representative trouble shooting the monitoring system. It appears there are no voltage <br />reading, thus the sensors are unable to send messages to the Incon. Incon no longer produces this <br />monitoring system and there are no replacement parts. The underground storage tank system shall be <br />operated to prevent unauthorized releases. <br />- An approved permit SR0065874 dated 10/15/12 was taken out to replace the existing Incon system & <br />sensors with a Veeder-Root monitoring system & sensors. The work is planned in the next few days. <br />Fuel station is to remain closed & no diesel deposition is allowed into the tank until monitoring <br />system is repaired and tested under inspection of inspector. Provide copy, for file and inspector, of the <br />new Monitoring Plan once system is replaced. <br />- Caution tape is placed around entire dispenser. All master dispensers are chained and locked. Satelite <br />dispenser cannot dispense fuel. Turbine breaker is turned off. <br />- Current Inventory diesel: Gross 11357.5 gal. Net 11288 gal. Product level 65.467 inches. Ullage <br />8804.9 gal <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector.. Received By: Title: <br />PHn 23-02 Rev 04119/'12 Page 3 UST INSPECTION REPOR <br />
The URL can be used to link to this page
Your browser does not support the video tag.