My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 11:43:46 AM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> SWRCB,January 2002 Page_of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: x Tank Manufacturer 0 Industry Standard 0 Professional Engineer <br /> 11 Other(Specify) <br /> Test Method Used: 0 Pressure x Vacuum El Hydrostatic <br /> 11 Other(Specify) <br /> Test Equipment Used:Dwyer Manometer Equipment Resolution:+/-2% In <br /> Test <br /> Equipment <br /> Tank# I Tank# Tank# Tank# <br /> I Is <br /> s Tank Exempt From Testing?' x Yes 0 No 0 Yes 0 No 0 Yes ONo 0 Yes 0 No <br /> T <br /> TankC p� <br /> ank Capacity: <br /> Tank Material: <br /> Tank Manufacturer: <br /> Product Stored: <br /> Wait time between applying <br /> pressure/vacuum/water and 30 min 30 min 30 min 30 min <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(Ri): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: I hour I hour I hour I hour <br /> Change in Reading(RF-Ri): <br /> Pass/Fail Threshold or Criteria: No less than I" No less than I" No less than I" No less than I" <br /> Test Result: 0 Pass 0 Fail 0 Pass 0 Fail 0 Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA <br /> Was sensor properly replaced and x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Annular space is wet <br /> C2 1=f% 111on <br /> nVM%09=1 V LMW <br /> JAN 0 8 2018 <br /> ENMONMENTAt HEALTIJ <br /> PFPUITIQI:o <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.