2300 - Underground Storage Tank Program
>
PR0507837
>
COMPLIANCE INFO_1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:32:59 PM
Creation date
6/3/2020 9:58:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507837_3940 N TRACY_1998-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIPING SUMP CONTAINMENTTESTING <br />Test Metflod By: 0 Manufacturer • Industrystandard Professional Engr. O ether (see below) <br />Test Method USeS: 0 Pressure Q Vacuum i Hydrostatic 0 f)4her{seebelow) <br />Measuring Equipment Used: Leve Chang@ lndlcator > ;(Caldwell System 2001 / Walton Engineering) <br />Description Talnk #1 TAnk #2 TAnk 3S Tank #4S <br />> Sump Material <br />FRP <br />FRP <br />FRP <br />FRP <br />Sump Diameter (inches) <br />42" <br />42" <br />42" <br />42" <br />Sump Depth (inches) <br />62" <br />60" <br />67" <br />70" <br />Product Stored <br />Gasoline - 87 <br />Gasoline - 9/ <br />Diesel <br />Diesel <br />Height from tank top to highest <br />14" <br />15" <br />20" <br />20" <br />piping penetration <br />Height from tank top to lowest <br />9" <br />9" <br />9" <br />9" <br />electrical penetration <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Wet <br />Wet <br />Portion of sump tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Is system programed for fail-safe operation? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Wait time for water level to stabilize (hr:min) <br />0:25 <br />0:16 <br />0:12 <br />0:10 <br />Depth of water level from tank top (inches) <br />18" <br />18" <br />24" <br />24" <br />Test start time <br />11:00 AM <br />11:01 AM <br />11:02 AM <br />9:50 AM <br />Test end time <br />11:30 AM <br />11:31 AM <br />11:32 AM <br />10:20 AM <br />Test duration (hr:min) <br />0:30 <br />0:300:30 <br />0:30 <br />Change in water level (± 0.000 inches) <br />0.000 <br />0.000 <br />0.000 <br />0.000 <br />Pass/Fail threshold (0.005 inches Hr.) <br />0.005 <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />PASS <br />Comments: <br />0 2002 Watton Engineering, Inc. <br />