Page 2 of 3 <br />(209) 468-3451 <br />kfoley. n_r <br />From: Mike Robertson [mailto:mike@robertsonengineering.net] <br />Sent: Monday, May 09, 20114:23 PM <br />To: Kasey Foley [EH]; Thuy Tran [EH] <br />Subject: RE: TRACY TRUCK & AUTO <br />The contractor is intending to install a single wall sump. I do not believe we had any double wall sump reference on our plans. The <br />double wall reference you may be referring to is in the UL letter, whereby, they were referring to their testing of the sumps and they <br />indicated the double wall was constructed with the same material as the single wall sumps. The manufacturer recommends the use of UV <br />coating and we agree. <br />There is not a UL approval for the above ground application, but it has been an industry standard. The UL letter I provided to you <br />indicates the testing that was done for the product and the materials used in the product. The letter further went on to indicate that the <br />product is suitable for UL listing. Fiberglass transition sumps were developed using the same penetration fittings and materials that were <br />used for tank sumps. Since the fiberglass tank sumps had already proven that they could be tested and the materials were compatible <br />With the fuel, it was a logical extension to make transition sumps out of the same materials, using the same penetration fittings. <br />Fiberglass transition sumps have been widely used in the industry and in many counties, including San Joaquin, in making the transition <br />from underground to above ground fuel piping for the past8 or 9 years. The ease with which fiberglass transition sumps can be installed <br />to provide acceptable test and containment results, have made them the industry standard for piping transitions. <br />Hopefully, this clarifies the information regarding UL approval and the industry use of the fiberglass products as transition sumps. <br />Mike Robertson <br />ROBERTSON ENGINEERING, inc. <br />2300 Elethards Drive, Suite L <br />Santa Rosa, CA 95405 <br />Phone: (707)523.7490 <br />Fax: (707)523.7499 <br />Email: mike@robertsQnen-gine-e n -q ne <br />From: Kasey Foley [EH] [mailto:KFoley@sjcehd.com] <br />Sent: Monday, May 09, 20113:49 PM <br />To: Mike Robertson; Thuy Tran [EH] <br />Subject: RE: TRACY TRUCK & AUTO <br />I reviewed your email and am confused by it. The sentence below implies you submitted an attachment that shows the Western Fiberglass transition sump has an approved UV <br />coating but I did not find that written anywhere: <br />"I have also attached the UL letter to Western Fiberglass for their sump. The above ground portion and lid have an approved UV coating <br />application, also provided by Western Fiberglass." <br />Also, the Western Fiberglass approval you submitted was for the double -walled sump but that isn't the cut sheet that was submitted to us. It shows a single -walled sump. <br />Do you have a UL approval for any portion of this sump to be used aboveground? <br />Thank you. <br />Kasey Foley, REHS <br />Program Coordinator <br />San Joaquin County Environmental Health Department <br />600 East Main Street <br />Stockton, CA 95202-3029 <br />(209)468-3451 <br />kfo11 (a sicehd.com <br />------ -- - - — ---- - -_- ___ _,_._.-.. <br />From: Mike Robertson [ma:lto:mike@robertsonengineering.net] <br />Sent: Monday, May 09, 20113:28 PM <br />To: Kasey Foley [EH]; Thuy Tran [EH] <br />Subject: TRACY TRUCK & AUTO <br />Hi Kasey & Thuy, <br />CJ and Chuck have been calling each day to see if you have approved the plan & Elite IV can pick up the Permit. I told Kevin Jorgensen <br />6/6/2011 <br />