Laserfiche WebLink
v0 <br />wAitem q Dim n ks ` Dims Di ,a 11 1►11 11 1► <br />Page 2 of 3 <br />Test Method Developed By: <br />❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures. <br />Equipment Resolution: <br />UDC#7/8 <br />UDC# UDC# UDC# <br />UDC Manufacturer: <br />UDC Material: <br />Fiberglass <br />UDC Depth: <br />30" <br />Height from UDC Bottom to Top <br />8" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />5" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />Fair <br />Portion of UDC Tested <br />Above highest <br />Above highest Above highest Above highest <br />penetration <br />penetration penetration penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />❑ Yes ❑ No ® NA <br />❑Yes ❑ No ® NA ❑ Yes ❑ No ® NA ❑ Yes ❑ No ® NA <br />product and water ? <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?" <br />ZYesNo NA <br />❑ ❑ ® <br />❑Y� ❑ No ® NA El Yes El No ®NA El Yes El No ®NA <br />Was fail-safe verified to be <br />operational?* <br />[I Yes ❑ No ®NA <br />❑Yes ❑ No ®NA ❑Yes ❑ No ®NA Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />30 minutes <br />30 minutes 30 minutes 30 minutes <br />starting test <br />Test Start Time: <br />9:10am <br />Initial Reading (RI): <br />3.2161 <br />Test End Time: <br />9:25am <br />Final Reading (RF): <br />3.2170 <br />Test Duration: <br />15 min <br />Change in Reading (RF-Ri): <br />0.00090 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 0.002 0.002 <br />T iil .. ter#MeeP <br />r. E wy <br />fi <br />Was sensor removed for testing? <br />®Yes [-]No ❑ NA <br />®Yes ❑No [:]NA ®Yes ❑No ❑ NA} ®Yes []No ❑ NA <br />Was sensor properly replaced and <br />®yes []No ❑ NA <br />®Yes ❑No ❑NA ®Yes ❑No ❑ NA ®Yes❑ No NA <br />❑ <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Repairs made pursuant to Permit #SR0065794 <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />