Laserfiche WebLink
LINE LEA%DETECTOR (LLD) TEST REPO - <br />TEST DATE: September 11, 2015 SEP 21 2015 <br />A1. FACILITY <br />Name Teichert Mobile Equipment <br />Address 120 Frank Circle, Stockton, CA 95206 <br />Phone # 916-366-8631 <br />Contact Steve Schamaun <br />A2. OWNER ENVIRONMENTAL. <br />Name Teichert Construction Iscp,-u I,���'aTeAcnIT <br />Address P.O. Box 15002, Sacramento, CA 95851 <br />Phone # 916-386-3767 <br />Contact Steve Schamaun <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />1 <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />WO -7 Used Oil <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />August 28, 2015 <br />0848480-001 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Stacy Rivera <br />Functional Element Holding (psi) <br />Contact <br />Veronica Freitas <br />Phone # <br />209-468-8257 <br />55 <br />Phone # <br />916-373-1166 <br />I. LINE LEAK DETECTOR TEST RESULTS 7 <br />Tcc4 I I—A- D -A 1-6-4 CV -17-6 0....a...... <br />J. COMMENTS: <br />WALTON <br />Signature: <br />ENGINEERING, INC. <br />Technician: Curtis Carpenter / B37258 8020679 Date: September 11, 2015 <br />3 <br />4 <br />Lube 3030011 <br />- - <br />Tank number <br />1 <br />Product contained <br />C-1 Diesel <br />Kj <br />WO -7 Used Oil <br />Leak Detector Type <br />ELLD <br />Leak detector make/model <br />0848480-001 <br />Serial number <br />H96085 <br />270880 <br />Functional Element Holding (psi) <br />30 <br />28 <br />Resiliency (ml) <br />55 <br />55 <br />Test leak rate (gph) <br />3.00 <br />3.00 <br />Pump pressure (psi) <br />18 <br />18 <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />0 <br />18 <br />0 <br />18 <br />Length of Restriction Test (seconds) <br />0 <br />0 <br />Full Flow Opening time (seconds) <br />0 <br />0 <br />TEST RESULT <br />PASS <br />PASS <br />5 <br />Tank number <br />6 <br />7 <br />Product contained <br />Lub 31 15 oil <br />Lub-32 Hydraulic <br />Diesel 5 HP <br />Leak Detector Type <br />ELLD <br />Leak detector make/model <br />0848480-001 <br />Serial number <br />114012 <br />Functional Element Holding (psi) <br />32 <br />Resiliency (ml) <br />55 <br />Test leak rate (gph) <br />3.00 <br />Pump pressure (psi) <br />78 <br />0 <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />78 <br />Length of Restriction Test (seconds) <br />0 <br />Full Flow Opening time (seconds) <br />0 <br />TEST RESULT <br />PASS <br />J. COMMENTS: <br />WALTON <br />Signature: <br />ENGINEERING, INC. <br />Technician: Curtis Carpenter / B37258 8020679 Date: September 11, 2015 <br />