F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I . . k <br />I if the entire depth of the UDC is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is"Wor"NA", the entire UDC must be tested. (See SWRCBLG-I60) <br />0 <br />SWRCB, January 2002 <br />Page _ of <br />7. <br />UNDER -DISPENSER CONTAROWNT TESTING <br />Tog Method Developed By, <br />0 UDC MOMIfilCtUrer <br />0 bdustry SMdard X Professional Engineer <br />0 Other (Specify) <br />Test Method Used: <br />0 Pressure <br />0 Vacuum <br />X Hydrostatic <br />0 Other (Spec#y) <br />Test Equipment Used: Caldwell Systems <br />Equipment Resolution: .005/30 min <br />UDC # 1&2 <br />UDC#3&4 <br />UDC# UDC# <br />UDC Manufacturer. <br />western <br />Western <br />UDC Material: <br />Fiberglass <br />Fl ass <br />UDC Depth: <br />32" <br />33" <br />Height from UDC Bottom to Top <br />IT, <br />12" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />14?' <br />15" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Dry <br />Dry <br />testing - <br />Portion of UDC Tested <br />2" above <br />Highest <br />piping <br />Penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />x Yes 0 No 0 NA <br />x Yes ONo DNA <br />OYes OM DNA <br />0 Yes 0 No 0 NA <br />roduci and water )?' <br />Turbine shutdown response time <br />Is system programmed for fail- <br />x Yes 0 No 0 NA <br />x Yes ONo DNA <br />OYes ONo DNA <br />0 Yes 0 No 0 NA <br />safe shutdown?* <br />Was &H -safe verified to be <br />D Yes x No 0 NA <br />0 Yes xNo DNA <br />OYes OM DNA <br />0 Yes 0 No 0 NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />5 min <br />5 min <br />5 min <br />5 min <br />starting test <br />Test Start Time: <br />10--40 <br />11:20 <br />Initial Reading (114): <br />.00" <br />.00" <br />.00" <br />.00" <br />Test End Time: <br />11:10 <br />11:50 <br />Final Reading (RF): <br />.00 <br />.00 <br />Test Duration: <br />30 min <br />30 min <br />30 min <br />30 min <br />Change in Readin (RF -R4): <br />.00 <br />.00 <br />Pass/Fad TIreshold or Criteria. <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />.005130 min <br />Test Re=W <br />x Pass 0 Fait <br />x Pass 0 Fan <br />0 Pass 0 Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />xYes ONo DNA <br />xYes ONo DNA <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />Was sensor property replaced and <br />,verified functional after!!nggL? <br />xYes ONo DNA <br />I <br />xYes ONoONA <br />xYes ONo OKA x Yes 0 No 0 NA <br />I I <br />Comments — (mdude information on repairs made prior to ;Wft and recommendedforfaW tests) <br />I if the entire depth of the UDC is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is"Wor"NA", the entire UDC must be tested. (See SWRCBLG-I60) <br />
The URL can be used to link to this page
Your browser does not support the video tag.