COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:11:49 PM
Creation date
6/3/2020 9:59:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0515365_120 FRANK WEST_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page_of <br /> 6. PIPING SUW TESTING <br /> Test Method Developed By. 0 Sump Manufacturer 0 Industry Standard X Professional Engineer <br /> 0 Other(Spedj) <br /> Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: Caldwell Systems Equipment Resolution: .005/30 min <br /> Sump 'Gas Sump#2 Diesel Sump#3 Diesel Sump# <br /> SE <br /> pDiam <br /> e <br /> ter. � <br /> 46146746" <br /> Sp Depth5477 5511 5771 <br /> Sup Material: <br /> Fiberglass Fiberglass Fiberglass <br /> Height from Tank to Top of 22 22" 1811 <br /> Highest Pi in <br /> Height from Tank Top to Lowest 2972 30" 2511 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry Dry Dry <br /> Portion of Sump Tested' 2"above Highest piping penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both xYes ONo DNA xYes ONoONA x Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> roduct and water)?' <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> shutdown?* <br /> Was fail-safe verified to be 0 Yes x No 0 NA 11 Yes x No 0 NA 0 Yes x No 0 NA 0 Yes 0 No 0 NA <br /> 2perational?' <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min 5 min 5 min <br /> test: <br /> Test Start Time: 8:55 9:55 10:45 <br /> Initial Reading(RO: .001, .0019 .001, .001, <br /> Test End Time: 9:25 10:25 11:15 <br /> Final Reading(RF): .00 .00 .00 <br /> Test Duration: 30 min 30 min 30 min 30 min <br /> Change in Reading(RF-R4): .00 .00 .00 <br /> Pass/Fail Threshold or Criteria: .005/30 min .005/30 min .005/30 min .005/30 min <br /> Test Result x Pass 0 Fait x Pass 0 Fail x Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> Was sensor properly replaced and xYes ONo DNA , x Yes 0 No 0 NA x Yes 0 No O,NA 0 Yes 0 No 0 NA <br /> verified functional <br /> CommentS—(include information on re <br /> pairs made prior to lafing, and recommended follow-u r d <br /> �u fo faile tests mom <br /> D P rl:-- I XIEL" <br /> I a LMM 114"Ov A- 9 V <br /> j A 1-3 2017 <br /> r:KixnPnNME-NTAL H ALTH <br /> DEPARTMENT <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to My of the questions indicated with an <br /> asterisk(*)is"ATO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />