My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:05:39 PM
Creation date
6/3/2020 10:00:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2000-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONIT NG SYSTEM CERTIFI TION <br /> se By All Jurisdictions Within the State of Califom <br /> Authority Cited:Chapter 6.7, th and Safety Code;Chapter 16,Division 3 Title 23, ifomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name:CHEVRON 209167 City: MANTECA CA Zip:95336 <br /> Site Address: 1234 YOSEMITE AVE Contact Phone No: 824-7433 <br /> Date of Testing/Service: 05/24/2005 <br /> Facility Contact Person: MANAGER-KIM <br /> Make/Model of Monitoring System:TLS-350 Work Order Number: 2236535 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1-91 Tank ID: 2-87 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 409 X1 Annular Space or Vault Sensor. Model: 409 <br /> �( Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: 206 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> 71 Electronic Line Leak Detector. Model: PLLD X Electronic Line Leak Detector. Model: PLLD <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TanklD: TanklD: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s) Model:208 <br /> ®Shear Valve(s). X Shear Valve(s) <br /> ®Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser lD: 5/6 Dispenser ID: 7/8 <br /> M Dispenser Containment Sensor(s) Model:208 71 Dispenser Containment Sensor(s). Model:208 <br /> ® Shear Valve(s). E Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: 11/12 <br /> QDispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s). Model:208 <br /> ® Shear Valve(s). X Shear Valve(s). <br /> 10 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ®System set-upX�Alarm history report <br /> Technician Name(print): DOUGLAS HARTY Signature: <br /> Certification No.: 006-05-0253 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 05/24/2005 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.