My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2006-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:40:58 PM
Creation date
6/3/2020 10:00:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2010
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2006-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
433
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> r <br /> E <br /> Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: D Sump Manufacturer ®Industry Standard D Professional Engineer <br /> a D Other(Specify) <br /> Test Method Used: D Pressure D Vacuum ®Hydrostatic I <br /> D Other(Spec) <br /> Test Equipment Used: Wayne Perry inc. i Equipment Resolution:.0007" j <br /> I <br /> Sump# IT-7 Sump# j Sump# Sump# <br /> Sump Diameter: <br /> Sump Depth: <br /> Sump Material: <br /> Height from Tank Top to Top of » j <br /> Highest Piping Penetration: f Z » l <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to testing: tJ <br /> Portion of Sum Tested' 2' ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> Sump PIPING PENETRATION PIPING PENETRATION PIPING PENETRATION <br /> Does turbine shut down when <br /> sump sensor detects liquid(both D Yes D No ®NA D Yes D No ®NA D Yes D No ®NA D Yes D No D NA <br /> product and water)?' If <br /> Turbine shutdown response time NA NA NA <br /> Is system programmed for fail-safe D Yes DNo ®NA D Yes D No ®NA D Yes DNo ®NA D Yes ONO DNA <br /> shutdown? <br /> Was fail-safe verified to be' D Yes DNo ®NA D Yes DNo ®NA D Yes DNo ®NA D Yes D No D NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> test: <br /> f <br /> Test Start Time: �'f fs, j <br /> Initial Reading(Rj): Z /,0.23 9'Z <br /> Test End Time: p.•,� 9- it <br /> Final Reading(RF): 2,� ,o 2.39p <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-R): voe), 3 2.5 <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 0.0020 1 -0.0020 -0.0020 1 -0.0020 -0.0020 -0.0020 <br /> Test Result: N Pass D Fail ® Pass D Fail D Pass _D Fail ❑ Pass D Fail j <br /> i <br /> Was sensor removed for testing? ®Yes D No D NA ®Yes D No D NA N Yes D No D NA ®Yes D No D NA <br /> Was sensor properly replaced and j <br /> verified functional ager testing? D Yes D No D NA ®Yes DNo DNA ®Yes D No DNA ®Yes D No D NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for•failed tests) <br /> i <br /> Chevron ##209167 <br /> 234 Yosemite Ave i <br /> Manteca, Ca <br /> D8057 SB989 j <br /> 3 <br /> 1 <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.