COMPLIANCE INFO_2006-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2006-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:40:58 PM
Creation date
6/3/2020 10:00:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2010
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2006-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
433
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> l <br /> Page of <br /> f <br /> 7.UNDER-DISPENSER CONTAINMENT C TESTING <br /> .Test Method Developed By: UPC Manufacturer El Industry.Standard ® Professional Engineer ❑ <br /> Other(Spec) <br /> Test Method Used:. Pressure ❑ Vacuum ❑ Hydrostatic M <br /> Other(Spec) t <br /> Test EquipmentUsed: Wayne Perry Inc. See Attached Testing Results Equipment Resolution:.00007 <br /> Under-Dispenser Containment Number Below <br /> 7 -» <br /> UDC Manufacturer: <br /> UDC Material: <br /> UDC Depth: z 2 7 ° 27" 6' 7" '217 <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: 7 <br /> Height from UDC Bottom to .5' <br /> Lowest Electrical Penetration: <br /> .:Condition of UDC prior to <br /> PortlonofUDC Tested 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine shut down when ❑Yes❑ No NAM ❑Yes❑ No NAM ❑Yes❑ No NAM ❑Yes❑ No NAM <br /> UDC sensor detects liquid, f <br /> --_ _Turt}ine shutdown response times 0-Yes E] No NA® ❑Yes❑-No-NA(O-- ❑Yes❑-No-NA®—---❑-Yes❑-No-NA®_ <br /> Is system programmed for fail- ❑Yes❑ No NAM ❑Yes❑ No NAM ❑Yes❑ No NAM ❑Yes❑ No NAM <br /> safe shutdown?' <br /> Was fail-safe verified to be <br /> ❑Yes No NAM ❑Yes❑ Na NA® ❑Yes ElNo NA® ❑Yes ElNo NAM <br /> o erational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time; <br /> Initial Reading(R): 10,13s S, -11,3/ /15%RzzS o.6073 to,92,70 et 73?r-7 <br /> Test End Time: 1/-127 z;e�® IZ.'� 2= 3eD Z`3 <br /> Final Reading(RF): 3V9-Y2 i v3.9ZzY Io.6a o.977c3 7,919-7 I <br /> Test Duration: 15 Min 15 Min I5 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-RI): oo ,, ,VgiD,37 VOCD.517 z,0,qe4> <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 0.0020 -0.0020 40020 -0.0020 -0.0020 -0.0020 <br /> Test Result' Pass ®•.P..a;ss Pass $ass E Pass Pass ❑ Pass ❑ Pass <br /> Fai[ ❑ Fait ❑ Fail ❑ Fail ❑`.Fail ❑ 'Fai[ Fail ❑ Fail <br /> Was sensor removed for testing? M Yes❑ No NA❑ M Yes❑ No NA❑ M Yes❑ No NAE M Yes❑ No NA❑ <br /> Was sensor properly replaced and M Yes E No NA❑ M Yes❑ No NA❑ M Yes❑ No NA❑ M Yes❑.No NAD <br /> verified functional after testing? <br /> Comments—(include in ormation on repairs made prior to testing, and recommended follow-up for ailed tests) <br /> . I <br /> Chevron *209167 I <br /> 1234 Yosemite Ave <br /> anteca, Ca <br /> 08057 SB989 <br /> i <br /> I <br /> . I <br /> a <br />